C–VirtualNIC Interface Configuration and Administration<br />

VirtualNIC Interface Configuration and Administration<br />

controller[ 2]<br />

GUID: 00066a02de000070<br />

vendor ID: 00066a<br />

device ID: 000030<br />

IO class : 2000<br />

ID: EVIC in Chassis 0x00066a00db00001e, Slot 1, Ioc 2<br />

service entries: 2<br />

service[ 0]: 1000066a00000002 /<br />

InfiniNIC.InfiniConSys.Control:02<br />

service[ 1]: 1000066a00000102 /<br />

InfiniNIC.InfiniConSys.Data:02<br />

Editing the VirtualNIC Configuration file<br />

Look at the qlgc_vnic.cfg.sample file to see how VNIC configuration files<br />

are written. This file can be found with the OFED documentation, or in the<br />

qlgc_vnictools subdirectory of the <strong>QLogic</strong> <strong>OFED+</strong> <strong>Host</strong> <strong>Software</strong><br />

download. You can use this configuration file as the basis for creating a<br />

configuration file by replacing the destination global identifier (DGID),<br />

IOCGUID, and IOCSTRING values with those of the EVIC/VEx IOCs<br />

present on your fabric.<br />

<strong>QLogic</strong> recommends using the DGID of the EVIC/VEx IOC, as it ensures the<br />

quickest startup of the VNIC service. When DGID is specified, the IOCGUID<br />

must also be specified. For more details, see the qlgc_vnic.cfg sample<br />

file.<br />

1. Edit the VirtualNIC configuration file, /etc/infiniband/qlgc_vnic.cfg.<br />

For each IOC connection, add a CREATE block to the file using the following<br />

format:<br />

{CREATE; NAME="eioc2";<br />

PRIMARY={IOCGUID=0x66A0130000105; INSTANCE=0; PORT=1; }<br />

SECONDARY={IOCGUID=0x66A013000010C; INSTANCE=0; PORT=2;}<br />

}<br />

NOTE:<br />

The qlgc_vnic.cfg file is case and format sensitive.<br />