G–ULP Troubleshooting<br />

Troubleshooting SRP Issues<br />

Solution:<br />

Perhaps an interswitch cable has been disconnected, or the VIO hardware is<br />

offline, or the Chassis/Slot does not contain a VIO hardware card. Instead of<br />

looking at this file, use the ib_qlgc_srp_query command to verify that the<br />

desired adapter port is in the active state.<br />

NOTE:<br />

It is normal to see the "Can not find a path" message when the system<br />

first boots up. Sometimes SRP comes up before the subnet manager has<br />

brought the port state of the adapter port to active. If the adapter port is not<br />

active, SRP will not be able to find the VIO hardware card. Use the<br />

appropriate OFED command to show the port state.<br />

Session in 'Connection Rejected' state<br />

Problem:<br />

The session is in the 'Connection Rejected' state according to<br />

/var/log/messages. If the session is part of a multi-session adapter,<br />

ib_qlgc_srp_stats shows it in the "Connection Rejected" state.<br />

A host displays<br />

"Connection Failed for Session X: IBT Code = 0x0<br />

"Connection Failed for Session X: SRP Code = 0x1003<br />

"Connection Rejected"<br />

D000046-005 B G-9