3–TrueScale Cluster Setup and Administration<br />

Checking Cluster and <strong>Software</strong> Status<br />

iba_opp_query<br />

iba_opp_query is used to check the operation of the Distributed SA. You can run it<br />

from any node to verify that the replica on that node is working correctly. See<br />

“iba_opp_query” on page I-4 for detailed usage information.<br />

# iba_opp_query --slid 0x31 --dlid 0x75 --sid 0x107<br />

Query Parameters:<br />

resv1<br />

0x0000000000000107<br />

dgid ::<br />

sgid ::<br />

dlid<br />

0x75<br />

slid<br />

0x31<br />

hop<br />

0x0<br />

flow<br />

0x0<br />

tclass<br />

0x0<br />

num_path<br />

0x0<br />

pkey<br />

0x0<br />

qos_class<br />

0x0<br />

sl<br />

0x0<br />

mtu<br />

0x0<br />

rate<br />

0x0<br />

pkt_life<br />

0x0<br />

preference<br />

0x0<br />

resv2<br />

0x0<br />

resv3<br />

0x0<br />

Using HCA qib0<br />

Result:<br />

resv1<br />

0x0000000000000107<br />

dgid<br />

fe80::11:7500:79:e54a<br />

sgid<br />

fe80::11:7500:79:e416<br />

dlid<br />

0x75<br />

slid<br />

0x31<br />

hop<br />

0x0<br />

flow<br />

0x0<br />

tclass<br />

0x0<br />

num_path<br />

0x0<br />

pkey<br />

0xffff<br />

qos_class<br />

0x0<br />

sl<br />

0x1<br />

mtu<br />

0x4<br />

D000046-005 B 3-35