F–Troubleshooting<br />

<strong>QLogic</strong> MPI Troubleshooting<br />

The following message indicates a mismatch between the <strong>QLogic</strong> interconnect<br />

hardware in use and the version where the software was compiled:<br />

Number of buffer avail registers is wrong; have n, expected m<br />

build mismatch, tidmap has n bits, ts_map m<br />

These messages indicate a mismatch between the InfiniPath software and<br />

hardware versions. Consult Technical Support after verifying that current drivers<br />

and libraries are installed.<br />

The following examples are all informative messages about driver initialization<br />

problems. They are not necessarily fatal themselves, but may indicate problems<br />

that interfere with the application. In the actual printed output, all of the messages<br />

are prefixed with the name of the function that produced them.<br />

assign_port command failed: str<br />

Failed to get LID for unit u: str<br />

Failed to get number of units: str<br />

GETPORT ioctl failed: str<br />

can't allocate memory for ipath_ctrl: str<br />

can't stat infinipath device to determine type: str<br />

file descriptor is not for a real device, failing<br />

get info ioctl failed: str<br />

ipath_get_num_units called before init<br />

ipath_get_unit_lid called before init<br />

mmap of egr bufs from h failed: str<br />

mmap of pio buffers at %llx failed: str<br />

mmap of pioavail registers (%llx) failed: str<br />

mmap of rcvhdr q failed: str<br />

mmap of user registers at %llx failed: str<br />

userinit command failed: str<br />

Failed to set close on exec for device: str<br />

NOTE:<br />

These messages should never occur. If they do, notify Technical Support.<br />

The following message indicates that a node program may not be processing<br />

incoming packets, perhaps due to a very high system load:<br />

eager array full after overflow, flushing (head h, tail t)<br />

The following error messages should rarely occur; they indicate internal software<br />

problems:<br />

ExpSend opcode h tid=j, rhf_error k: str<br />

Asked to set timeout w/delay l, gives time in past (t2 < t1)<br />

Error in sending packet: str<br />

In this case, str can give additional information about why the failure occurred.<br />

F-26 D000046-005 B