RS-232C channel assignment<br />

PGM 2<br />

Your register is equipped with two RS-232C interfaces. If you use the communication functions, the channel<br />

number of each RS-232C interface must be programmed by using the following procedure.<br />

To activate the communication functions, please consult your dealer.<br />

2690<br />

Procedure<br />

To program any function no. (**P: 1 - 3)<br />

2690 ** P<br />

*ABCD<br />

. @ @ t Ç<br />

** P: 1<br />

(1 - 3)<br />

To program zero<br />

* Item: Selection: Entry:<br />

A Channel no. for the ON-LINE communication Not connected 0<br />

Standard channel 1 1<br />

Standard channel 2 2<br />

B Channel no. for print data sending (CVM) Not connected 0<br />

Standard channel 1 1<br />

Standard channel 2 2<br />

C Channel no. for the scale Not connected 0<br />

Standard channel 1 1<br />

Standard channel 2 2<br />

D Channel no. for the coin dispenser Not connected 0<br />

Standard channel 1 1<br />

Standard channel 2 2<br />

** P: 2<br />

* Item: Selection: Entry:<br />

A Channel no. for the barcode reader Not connected 0<br />

Standard channel 1 1<br />

Standard channel 2 2<br />

B Channel no. for the remote printer 1 Not connected 0<br />

Standard channel 1 1<br />

Standard channel 2 2<br />

C Channel no. for the remote printer 2 Not connected 0<br />

Standard channel 1 1<br />

Standard channel 2 2<br />

D Always enter 0. 0<br />

Note<br />

For the barcode reader, when you use the model <strong>ER</strong>-A6HS1, always select the standard channel 1.<br />

166<br />

** P: 3<br />

* Item: Selection: Entry:<br />

A Always enter 0. 0<br />

B Channel no. for the slip printer TM-295 Not connected 0<br />

(see below for the selection) Standard channel 1 1<br />

Standard channel 2 2<br />

C Always enter 0. 0<br />

D Channel no. for CAT Not connected 0<br />

Standard channel 1 1<br />

Standard channel 2 2<br />

Channel no. for the slip printer TM-295<br />

Select “Not connected” for internal printer (printing bills on receipt)<br />

Set “standard channel 1” or “standard channel 2” for TM-295 printer.<br />

Note<br />

• Never enter any number other than 0, 1 and 2.<br />

• The data backup function always uses standard channel 1.