RS-232C interface<br />

PGM 2<br />

6110<br />

6111<br />

6112<br />

6113<br />

6115<br />

6212<br />

6213<br />

6220<br />

Online terminal number<br />

Procedure<br />

Transmission line form system<br />

Procedure<br />

To program zero<br />

6110 Terminal no.<br />

. @ Ç<br />

(max. 6 digits)<br />

To program zero<br />

6111 *AB<br />

. @ Ç<br />

* Item: Selection: Entry:<br />

A Sending of the CI signal No 0<br />

Sending 1<br />

B Line form Full duplex system 0<br />

Half duplex system 1<br />

Functional programming<br />

Procedure<br />

6112 *A<br />

. @ Ç<br />

* Item: Selection: Entry:<br />

A Baud rate (38400/19200/9600/4800 bps) 4800 bps 4<br />

The selected baud rate is used for on-line 9600 bps 5<br />

communications. 19200 bps 6<br />

It is not used for the data backup function. 38400 bps 7<br />

Start code and end code<br />

Procedure<br />

6113 *ABCDEF<br />

. @ Ç<br />

* ABC: Start code (000 – 127)<br />

DEF: End code (000 – 127)<br />

Time out setting<br />

Procedure<br />

To program zero<br />

6115 Time out time<br />

. @<br />

Ç<br />

(1 – 255 sec)<br />