FREQUENTLY-USED FUNCTIONS<br />
5.3.2 Detection Timer<br />
Click “DETECTION”. In “DETECTION TIMER”, select “ON” to enable record timer, and<br />
select the day and time for this function.<br />
SCHEDULE SETTING<br />
RECORD DETECTION TIMER ON<br />
DETECTION 0 2 4 6 8 10 12 14 16 18 20 22 24<br />
SUN<br />
MON<br />
TUE<br />
WED<br />
THU<br />
FRI<br />
SAT<br />
EXIT<br />
X axis<br />
Y axis<br />
0 ~ 24 hours. Each time bar is 20 minutes.<br />
Monday ~ Sunday.<br />
5.4 Detection Setting<br />
Right-click to display the main menu, and select “ADVANCE CONFIG” “DETECTION”.<br />
ADVANCE CONFIG<br />
CANERA CH1 CH2 CH3 CH4 CH5 CH6 CH7 CH8 CH9 CH10 CH11 <br />
DETECTION LS 07<br />
ALERT SS 03<br />
NETWORK TS 02<br />
SNTP DET OFF<br />
DISPLAY ALARM OFF<br />
RECORD AREA EDIT<br />
REMOTE<br />
EXIT<br />
1) LS (Level of Sensitivity)<br />
“LS” is to set the sensitivity of comparing two different images. The smaller the<br />
value is, the higher sensitivity for motion detection. The highest sensitivity setting is<br />
00, and the lowest sensitivity setting is 15. The default value is 07.<br />
2) SS (Spatial Sensitivity)<br />
“SS” is to set the sensitivity for detecting the size of one object (the number of the<br />
grids) on the screen. The smaller the value is, the higher sensitivity for motion<br />
detection.<br />
The highest sensitivity setting is 00, and the lowest sensitivity setting is 15. The<br />
default setting is 03.<br />
22