132 Part CGENERAL TAB (OUTPUT PREFERENCES)Stop buttonstarts.Pulse output turns ON and OFF corresponding to the Start and Stop of the recording. Inother words, the Pulse output can only occur during a recording.When in this mode, and not recording, the ON button will display as yellow, indicating thatpulse output will automatically begin at the “Start” of the recording.Pulse outputting can be turned OFF during a recording, but it cannot be turned back ONuntil the end of the recording.When a Repeat sequence is running, pressing the OFF button will turn OFF the output forthe entire recording sequence and the button will display as OFF until after the lastsequence, when the switch will display as yellow ON (automatic start) indicating that pulseoutput will begin again at the “Start” of the next recording sequence. You cannot turn pulseoutputting back ON during a repeated recording sequence.When the acquisition stops, all stimulator pulses will cease, regardless of the OutputControl panel settings.The pulse train will stop concurrent with the end of the acquisition, even if the specifiedpulse train is not completed before the acquisition ends. When a new acquisition isstarted, the pulse train will start from the beginning.In this mode, no changes can be made in the Output Control panel until the recording stops.Changes made after recording stops will take effect when a new recording is started.When a pulse is sent out, the marker label and indicator arrow will be generated (if themarker preference is turned ON and markers are displayed).After initial delayAfter initial delay of … is enabled only when “Initiate pulse sequence with Recording” ischosen. Specify a delay interval from the start of recording to the start of the first pulse.This is useful for viewing data prior to the stimulus pulse. The BIOPAC output devicedetermines the delay range.INITIAL PULSE DELAY MP36/35 MP30 or <strong>BSL</strong>STMRange 0 - 100 milliseconds 0 or .5 - 100 milliseconds*Resolution 10 microseconds 1.953 microseconds*Entries greater than 0 milliseconds must be at least 0.5 milliseconds.Visit the online support center at www.biopac.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!