10.07.2015 Views

BSL PRO Software Guide - Biopac

BSL PRO Software Guide - Biopac

BSL PRO Software Guide - Biopac

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

276 Part EAnalog Preset NameChannel LabelApplicable Calc. PresetsGainXHardwareFiltersAC or DC.05 or .5 HP1K or 5K LPIIRFiltersType,Freq., QScaling(Mapping)UnitslabelRecommendedCalibration &Sample Rate(Samples/sec)Stimulator - <strong>BSL</strong>STM (0 – 100 Volts )StimulatorUse for recording the “ReferenceOutput” Pulse of the BIOPAC <strong>BSL</strong>STMStimulator. This preset is used when theRange switch on the front of the<strong>BSL</strong>STM is in the “0-100V” position. Theamplitude of the pulse reflects theStimulator output voltage.200 DC5K LPNone 0 mV to 050 mV to 100VoltsCalibration:optional toobtain greateraccuracy.Min. SampleRate: 200 S/SNote that there will be some overshooton the leading edge of the pulse. If thisis not desirable, then change the AnalogFilter to 1KHz.Stroboscope Flash (TSD122)200 DCNone -50 mV to -10VoltsStroboscope Flash5K LP50 mV to 10<strong>BSL</strong> 3.7.3 or below – not in <strong>BSL</strong> 3.7.7:SuperLab Sync. (SS44L)200 DCNone 0 mV to 0VoltsSuperLab Interface Cable for MP301K LP25 mV to 5SuperLab Sync.Note: Superlab interface assembly forMP36/35 (consists of 1-SS59L; seeBNC SS9L preset)SwitchPushbutton SwitchUse when recording Pushbutton SwitchState using BIOPAC SS10L PushButtonHandSwitch. This is useful for Responsetesting, etc.1,000 DC1K LPLP, 30,.707<strong>BSL</strong>F-1 mV to -11 mV to 1VoltsMin. SampleRate: 200 S/STemperature (deg. C)TemperatureMin. SampleRate: 100 S/SSkin Temperature (fast response)2,000 DCBP 0 uV to 32.22deg CResponse time = .6 secondsUse when recording Skin Temperaturein degrees Celsius using the BIOPACSS6L Temperature Transducer.1K LP1000 uV to35Calibration required**Temperature (deg. F)TemperatureUse when recording Skin Temperaturein degrees Fahrenheit using theBIOPAC SS6L TemperatureTransducer.2,000 DC1K LPBP 0 uV to 901000 uV to95deg FMin. SampleRate: 100 S/SCalibration required**Temperature (waterproof, vinyl)Response time = 1.1 secondsUse any preset from SS6L- - - - -Temperature Change (deg. C)Temperature Change2,000 AC.05 HP, 1KBP 0 uV to 01000 uV todeltadeg CMin. SampleRate: 100 S/SVisit the online support center at www.biopac.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!