10.07.2015 Views

BSL PRO Software Guide - Biopac

BSL PRO Software Guide - Biopac

BSL PRO Software Guide - Biopac

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Appendices 271Analog Preset NameChannel LabelApplicable Calc. PresetsGainXHardwareFiltersAC or DC.05 or .5 HP1K or 5K LPIIRFiltersType,Freq., QScaling(Mapping)UnitslabelRecommendedCalibration &Sample Rate(Samples/sec)presets to obtain real time Rate, R-waveamplitude, etc.Additional Calculation Channel Presetscan be created to filter out unwantedEMG interference.Electrodermal Activity (EDA), 0 - 35 HzEDA (0 – 35 Hz)EDA (GSR) finger electrodesEDA (GSR) with electrode pinch leads:Use any Preset from SS3LA2,000 DC1K LPBP 0 uV to 01000 uV to10microseimensCalibrationrequired**Min. SampleRate: 100 S/SUse when recording electrodermalactivity (galvanic skin response) usingthe BIOPAC SS3LA EDA (GSR)transducer. Changing baseline maymake this preset hard to work with. Ifonly changes in the EDA are desired,use the “EDA Change” preset._______________________________SCR setup: For skin resistance, use anExpression calculation channel to takethe reciprocal of conductance and thenapply proper scaling.Electrodermal Activity (EDA) ChangeEDA ChangeUse when recording changes inelectrodermal activity using the BIOPACSS3LA EDA (GSR) transducer. Baselinedrift is minimized with the .05 Hz HighPass filter.5,000 AC.05 HP, 1KLPBP 0 uV to 01000 uV to10deltamicroseimensMin. SampleRate: 100 S/SElectroencephalogram (EEG), .5 - 35 HzEEG (.5 – 35 Hz)Use when recording Human EEGsignals using the BIOPAC SS2LElectrode Leads.25,00020,000AC.5 HP, 1KLPBP -10 uV to -1010 uV to 10micro VMin. SampleRate: 100 S/SCan be used with the EEG Calculationpresets (alpha, beta, delta, and theta) toextract the specific EEG frequencybands.Electroencephalogram (EEG), .5 - 100Hz w/notchEEG (.5 - 100 Hz, w/notch)25,00020,000AC.5 HP, 1KLPLP, 100,.707<strong>BSL</strong>F-10 uV to -1010 uV to 10micro VNote: This bandwidth is needed forextracting the gamma frequency bandusing the calculation channel preset:EEG gamma (30 - 90 Hz).Electrogastrogram (EGG)EGG5,000 AC.05 HP, 1KLP DCBP -1000 uV to -11000 uV to 1mVElectromyogram (EMG), 5 - 250 Hzw/notchEMG (5 – 250 Hz w/notch)1,000 AC5 HPLP, 250,.707<strong>BSL</strong>F-1 mV to -11 mV to 1mVElectromyogram (EMG), 5 - 500 Hz 1,000 AC LP, 500, -1 mV to -1 mV

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!