266 Part EAppendix B — Table of Analog PresetsNotes * Notch Filter is either 50 Hz or 60 Hz as determined by the Line Frequency specified whenthe <strong>BSL</strong> <strong>PRO</strong> software was installed. It is used to filter out the interference signal introducedfrom electrical power sources.** The transducer must be calibrated before the recording begins. Typically this involves usingthe “scaling” dialog (accessible via MP UNIT > Setup Channels > View/Change Parameters >Scaling…), but more involved calibration may be required. Refer to the <strong>BSL</strong> Hardware <strong>Guide</strong> orApplication Notes available on the BIOPAC Web Site (www.biopac.com). The Band Stop Frequency will be 50 Hz or 60 Hz, based on the Line Frequency specifiedwhen the <strong>BSL</strong> <strong>PRO</strong> software was installed.Analog Preset NameChannel LabelApplicable Calc. PresetsDefaultGainXHardwareFiltersAC or DC.05 or .5 HP1K or 5K LPIIRFiltersType,Freq., QScaling(Mapping)UnitslabelRecommendedCalibration &Sample Rate(Samples/sec)This preset can be used as a starting point when no other preset is applicable orwhen input amplitude and offset are unknown. It is set to maximum bandwidth, anda low gain allowing one to record and view almost any Physiological signal thatfalls within a +-50 mV input range.Min. Sample Rate: 2X maximum frequency expected or desired.Accelerometer (5 g’s max.)Accelerometer (5 g), 3 CHUse with the BIOPAC SS26L, 0 to 5g,Accelerometer500 DC1K LPBP 11 mV to 110 mV to 0g’sCalibrationrequired**Min. SampleRate: 100 S/SAccelerometer (50 g’s max)Accelerometer (50 g), 3 CHUse with the BIOPAC SS27L, 0 to 50gAccelerometer.500 DC1K LPBP 7.5 mV to 106.5 mV to 0g’sCalibrationrequired**Min. SampleRate: 100 S/SAirflow (SS11LA)Airflow transducerCan be used with the “Lung Volume”Calculation Channel preset to obtainVolume data.5,000 DC1K LPBP -3000 uV to -103000 uV to10liters/secMin. SampleRate: 100 S/SAirflow (SS52L)Airflow (SS52L)SS52L System: Airflow (75 kg,exercising adult) Airflow1,000 DC1K LPBP 0 mV to 0192.5 mV to1liters/secAirflow (small mouse)Airflow (small mouse)SS45L System: Airflow (30 gm, smallmouse) Airflow1,000 DC1K LPBP 0 mV to 01.285 mV to10ml/secAirflow (mouse)Airflow (mouse)SS46L System: Airflow (50 gm, mouse)Airflow1,000 DC1K LPBP 0 mV to 00.770 mV to10ml/secAirflow (rat/guinea pig)Visit the online support center at www.biopac.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!