10.07.2015 Views

BSL PRO Software Guide - Biopac

BSL PRO Software Guide - Biopac

BSL PRO Software Guide - Biopac

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

270 Part EAnalog Preset NameChannel LabelApplicable Calc. PresetsGainXHardwareFiltersAC or DC.05 or .5 HP1K or 5K LPIIRFiltersType,Freq., QScaling(Mapping)UnitslabelRecommendedCalibration &Sample Rate(Samples/sec)Displacement (inches)500 DCBP 0 mV to 0inchesDisplacement; use with SS14L.1K LP1 mV to .394Displacement (AD Inst. DT-475)500 DCBP 0 mV to 0inchesDisplacement1K LP9 mV to 1Dissolved O 2 (<strong>BSL</strong>-TCI16)Dissolved O 2 using BIOPACRX<strong>PRO</strong>BE02 and Vernier (BT (RH)connector)200 DC1K LPBP 0 mV to 025 mV to 100% O2Earthworm Action PotentialEarthworm Action Potential10,000 AC5 Hz HP, 5HP, 5K LPHP, 50,.707-10 uV to -1010 uV to 10micro V 100,000Electrocardiogram (ECG), .05 - 35 HzUse when recording Human ECGsignals using the BIOPAC SS2LElectrode Leads. This preset willpreserve more of the ECG componentamplitude than the (.5 – 35 Hz) filter, butwith more baseline drift. Works well ifsubject is completely relaxed andmotionless.1000 AC.05 HP, 1KLPBP -1000 uV to -11000 uV to 1-1 mV to -11 mV to 1mVMin. SampleRate: 100 S/SCan be used with the ECG Calculationpresets to obtain real time Rate, R-waveamplitude, etc.Electrocardiogram (ECG), .05 - 100 Hz,AHA American Heart Assoc.ECG (.05 – 100 Hz, AHA)1,000 AC.05 HP, 1KLPLP, 100,.707-1000 uV to -11000 uV to 1mV-1 mV to -11 mV to 1Electrocardiogram (ECG), .05 - 150 HzECG (.05 – 150 Hz)Use when recording Human ECGsignals using the BIOPAC SS2LElectrode Leads. This preset is mainlyused when measuring amplitudes andtiming of the components of the ECG. Itcan only work if the subject iscompletely relaxed and motionless (nointerfering EMG signals), and no powerline (50/60 Hz) interference is present.1,000 AC.05 HP, 1KLPLP, 150,.707-1000 uV to -11000 uV to 1-1 mV to -11 mV to 1mVMin. SampleRate: 500 S/SElectrocardiogram (ECG), .5 - 35 HzECG (.5 – 35 Hz)Electrode Cable with 3 LeadsUse when recording Human ECGsignals using the BIOPAC SS2LElectrode Leads. This preset will give aclean recording with minimal baselinedrift, however the components of theECG may have a slight reduction inamplitude due to the added filters.1,000 AC.5 HP, 1KLPBP -1000 uV to -11000 uV to 1-1 mV to -11 mV to 1mVMin. SampleRate: 100 S/SCan be used with the ECG CalculationVisit the online support center at www.biopac.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!