10.07.2015 Views

cabarrus county board of commissioners regular meeting november ...

cabarrus county board of commissioners regular meeting november ...

cabarrus county board of commissioners regular meeting november ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

October 17, 2011 (Regular Meeting)Page2,001 - 3,000 121% 35,001 - 40,000 99%3,001 - 4,000 119% 40,001 - 50,000 98%4,001 - 5,000 116% 50,001 - 60,000 97%5,001 - 6,000 115% 60,001 - 70,000 96%6,001 - 7,000 114% 70,001 - 80,000 94%7,001 - 8,000 112% 80,001 - 100,000 92%8,001 - 10,000 110% 100,001 - 120,000 90%10,001 - 12,000 109% 120,001 - 140,000 88%12,001 - 14,000 107% 140,001 - 180,000 86%14,001 - 16,000 105% 180,001 - 225,000 84%16,001 - 18,000 104% 225,001 - 400,000 82%18,001 - 20,000 103% 400,001 - UP 80%REST ROOM - PLUMBING POINT SCHEDULEHEIGHT FACTORAREA PER FIXTURE POINTS HEIGHT FACTOR0 - 1159 5 8 - 9.9 .891160 - 2249 4 10 - 11.9 .92*2250 - 3249 3 12 - 13.9 .963250 - 4999 2 *14 - 15.9 1.005000 - UP 1 16 - 17.9 1.0418 - 19.9 1.08QUALITY ADJUSTMENT 20 - 21.9 1.1322 - 23.9 1.1801 MINIMUM .75 24 - 25.9 1.2302 BELOW AVERAGE .90 26 - 27.9 1.2803 AVERAGE* 1.00 28 - 29.9 1.3304 ABOVE AVERAGE 1.10 30 - 34.9 1.3805 ABOVE AVG/CUSTOM 1.30 35 - 39.9 1.5106 EXCELLENT 1.50 40 - 44.9 1.6445 - 49.9 1.77MARKET/DESIGN FACTOR 50 - 54.9 1.9055 - 59.92.0301 MARKET FACTOR 1 0.92 60 - 69.9 2.1602 MARKET FACTOR 2 0.96 70 - 79.92.4203 MARKET FACTOR 3* 1.00 80- 89.92.6804 MARKET FACTOR 4 1.04 90 - 98.92.8405 MARKET FACTOR 5 1.06 99 - UP2.8406 MARKET FACTOR 6 1.101007 MARKET FACTOR 7 1.15HEIGHT FACTOR X QUALITY FACTOR X SIZE FACTOR X MARKET FACTOR* Indicates the standard used for a 100 point structure.MODEL 07 COMMERCIAL MERCIAL- STRUCTURAL ELEMENT DATADRAFTFOUNDATION PTS ROOF STRUCTURE PTS HEATING FUEL PTS01 EARTH 0 08 IRREGULAR TRUSS 19 01 NONE 002 PIERS 2 09 BARJOIST 10 02 OIL/WD/COAL 003 CONT FOOTING D04 10 STEEL FRM, TRUSS* 11 03 GAS 104 SPREAD FOOTING* 6 11 BOWSTRING TRUSS 9 04 ELECTRIC* 105 SPECIAL FOOTING 10 12 REINFORCE CONC 13 05 SOLAR 1FLOOR SYSTEM 13 PRESTRESS CONC 14 HEATING TYPE01 NONE 0 ROOFING COVER 01 NONE 002 SLAB ON GRADE* 6 01 CORR/ SHEET METAL 2 02 BASEBOARD 503 SLAB ABOVE GRADE 12 02 ROLL COMP 2 03 AIR-NO-DUCT 304 PLYWOOD 10 03 COMPOSITION SHINGLE 3 04 AIR-DUCTED 605 WOOD 12 04 BLT UP TAR&GRVL* 4 05 RADIANT SUSPENDED 306 PLATFORM HGT 17 05 RUBBERIZED 9 06 HOTWATER 1007 STRUCT SLAB 17 06 ASBTS-FIBER SHG/CORR 4 07 STEAM 7EXTERIOR WALL 07 TILE CLAY 13 08 RADIANT ELECTRIC 501 SIDING MINIMUM 3 08 WOOD SHINGLE/SHAKE 7 09 RADIANT WATER 1102 CORR METAL LIGHT 5 09 COPPER 20 10 HEAT PUMP* 603 COMP OR WALL BRD 10 10 COMP. SHINGLE HEAVY 5 11 HEAT PUMP WALL UT 304 SIDING NO SHTG 14 11 SLATE 12 12 HEAT PUMP LOOP SYS 805 ASBTS-FIBER SHG/CORR 17 12 METAL PREFINISHED 7 AIR CONDITION TYPE06 BRD&BAT/PLW 16 13 METAL STANDING SEAM 12 01 NONE 007 CEMENT FIBER SID 19 14 TILE CONC/PLASTIC 9 02 WALL UNIT 308 MASONITE 18 15 ENAMEL/STAINLESS SHNG 14 03 CENTRAL* 609 WOOD ON SHTG 19 16 CEMENT FIBER SHINGLE 8 04 PACKAGE ROOF 610 ALUM, VINYL 19 INTERIOR WALL 05 CHILLED WATER 611 CONCRETE BLOCK 20 01 MASNRY/MIN 212 STUCCO 22 02 WALLBRD/WD/METAL 4 STRUCTURAL FRAME13 STUCCO SYNTHETIC 24 03 PLASTER 8 01 NONE 014 DESIGN VINYL 20 04 PLYWOOD PANEL 6 02 WOOD FRAME 1015 BRD&BAT 12"/WD SHG 20 05 DRYWALL/SHEETROCK* 8 03 PREFABRICATED 716 LOG 23 06 CUSTOM INTERIOR 16 04 MASONRY* 1217 CEDAR, REDWOOD 22 INTERIOR FLOOR COVER 05 RNFRD CONC 2918 SIDING MAXIMUM 28 01 NONE 0 06 STEEL 14A-1Page 160

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!