11.07.2015 Views

! j I I - National Roofing Contractors Association

! j I I - National Roofing Contractors Association

! j I I - National Roofing Contractors Association

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

SeamProcessing. --- ---'~--.~ ~Metal Roof Panels1. COMPANY NAME Allied Roof syst- Alllll8x Building Specialty Oivisi~2. PRODUcr NAME SS 2.5 Cot-R-Cap3. A~hltac1ural Applications (yea/no) yes yesStructural Applications (yes/no) yes yes4. PANEL CONFIGURATION4A. Panel Description Snap-~ Batten Structural Snap-~ Batten SeM48. Panel Materials, Thicknesses, and Finishes Thicknesses Finished or Unfinished Thicknesses Finished or Unfinished================ ============================== ================ ==============================galvanized stael (gs.) 24,26 Kynar 500, si l ic~ polyester, 22,24 Kynar 500I6'finishedstainless steel (gs.) 24,26gslvalume (ga.) 24,26 Kynar 500, silic~ polyester, 24 Kynar 500millslumlnlzed steel (ga.) 24,26aluminum (In.) 0.032,0.040 Kynar 500, si l ic~ polyester 0.032,0.040 Kynar 500anodized aluminum (In.) 0.032,0.040copper (oz.) 16,20 16,20terne metal (ga.) 24zinc (ga.) 244c. Maximum Length (If.) 60 1504D. Panel Widths (In.) 12,16,18 165. SYSTEMS REQUIREMENTSSA. Minimum Slope (in. per fl.) 1/4:12 1/2:12optionaloptional58. Solid Decking (requll9d, optional, or not used)5C. Underlayment (type or NA) 30-lb. felt or equivelent 30-lb. felt6. PANEL PROFILE Vertical Trape- Batten Other Vertical Trape- Batten Otherleg zoidel leg zoidelI I X I I X7. SEAM PROCESSING, HEIGHT, AND SEALANT Height(s) SeM Sealant Height(s) Seam Sealant(ins.) F=factoryapplied (ins.) F=factoryappliedE=field applied E=field appliedN=noneN=noneoverlappedcrimped (45 degree)roll formed (1S0 degrees)double roll formed (2 1S0 degrees)rollsndlock 21/2 F,Esnap-on cap X 2 1/2 F Esnap together'X 2 1/2 NS. FASTENING METHODSA. Through fastened, exposedS8. Through fastened, concealedSC. Clip, concealedfixed clipslip clipmoveable clip (designed allowable movement, Ins.) 2 1/2XXg. Specialty Applicationscurvedtaperedother10. Manufacturer/Product Data Engineering Year of licensed Kind of Engineering Year of licensed Kind ofSupport First Applicator Applicator Support First Applicator ApplicatorAvailable Commercial Agreement Training Available Commercial Agreement Training(yes/no) Use (yes/no) Available (yes/no) Use (yes/no) AvailableXyes 1984 yes field yes 1979 noForsaleslnformatlon,contact: 205-591-5105o. PickensFor technical information, contact: 205-591-1010l. Morris11. ASTM E331 Watar Infiltration Test Rasulta no penetratIon . at20 psffor 15 -. minutes no penetration .x,(jer -.- 5-gal.-per-hour spray at6.4 psf pressure differential12. ASTM E2S;, Air Infiltration Test Results leakage at seM not to exceed 0.005 cfm psf of maximum of 0.008 cu. ft. per minute per sq. ft.panel at 10 psf differential pressure with 6.24 psf pressure differential-- --13. FM-UL Wind Uplift Ratings for Any Specification Ul-90 Ul-90.14. See Appendix if Checked XNA = not applicable166

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!