11.07.2015 Views

! j I I - National Roofing Contractors Association

! j I I - National Roofing Contractors Association

! j I I - National Roofing Contractors Association

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

SeamProcessing~- ~-, ,-,--~ ""~._,~Metal Roof Panels1. COMPANY NAME Berridge Manufacturing Co. Berridge Manufacturing Co.2. PRODUCT NAME Cee-Lock P_l HR" panel3. Archltec1u181 Appllc8t1on8 (yuino) yes yesStructu181 Applications (yes/no) yes yes4. PANEL CONFIGURATION4A Panel Description Snap-on Standing Semi Corrugated Roof Panel48. Panel Materials, Thicknesses, and Finishes Thicknesses Finished or Unfinished Thicknesses Finished or Unfinished===============. ============================================= ==============================galvanized steel (ga.) 24 Kynar 500 24 Kynar 500stainless steel (ga.)galvalume (ga.) 24 Kynar 500 24 Kynar 500aluminized steel (ga.)aluminum (in.)anodized aluminum (in.)copper (oz.) 16terne metal (ga.)zinc (ga.)4C. Maximum Length (If.) 40 404D. Pan81 Widths (In.) 16 1/2 365. SYSTEMS REQUIREMENTSSA. Minimum Slope (in. per ft.) 1:12 1/2:12optIonal not used58. Solid Decking (required, optional, or not uoed)5c. Und8rlayment(typeorNA) 30-lb. felt or equiv8lent NA6. PANEL PROFILE Vertical Trape- Batten Dther Vertic81 Trape- B8tten Otherleg zoidal leg zoidalX I I I X I7. SEAM PROCESSING, HEIGHT, AND SEALANT Height(s) Se~ Sealant Height(s) Se~ Sealant(ins.) F=factoryawlied (ins.) F=factoryawliedE=field awlied E=field awliedN=noneN.noneoverlapped X I 1/4 Ecrimped (45 degree)roll formed (180 degrees)double roll formed (2 180 degrees)roll and locksnap-on capsnap together X I 1/2 N8. FASTENING METHOD8A Through fastened, exposedX88. Through fastened, concealed8C. Clip, concealedfixed clipslip clip X Xmoveable clip (designed 8110W8bl8 mov8ment, 1M.)9. Specl81ty Applicationscurvedtaperedother10. M8nuf8clurer/Produc1D818 Engineering Year of Licensed Kind of Engineering Year of Licensed Kind ofSuwort First Awlicator Awlicetor Suwort First Awlicator AWlic8torAvail8ble C~rcial Agreetrent Training Available C~rcial Agreetrent Training(yes/no) Use (yes/no) Avail8ble (yes/no) Use (yes/no) Avail8bleyes 1989 no field, yes 1988 no fieldFor sales information, contact: o. Ooyle video O. OoyleFor technic81lnformation, contact: R. Marks R. Marks11. ASTM E331 WeIer Inlllt18t1on Test Results none none12. ASTM E2B3 Air Inllltl8llon Test R8sults none none13. FM-UL Wind Uplift R8t1ngs tor Any Speclflc8tlon none UL-9014. See Appendix If CheckedNA = not 8ppllcable178. ~"k~~"","~

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!