11.07.2015 Views

! j I I - National Roofing Contractors Association

! j I I - National Roofing Contractors Association

! j I I - National Roofing Contractors Association

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

.51 Plata Shape, Dimensions, and M8I8r1al ~! ~ ! ~ ~ ! ~ ! ~Roof Fasteners: Concrete Decks1. Company NameFA8CO RIF/OIY. DEM8Y INDUSTRIESFIRESTONE BUILDING PRODUCTS2. Product Name INSUL-FIXX'14-10 FIRESTONE ALL PURPOSE3. Country 01 Manulecture U.S. U.S.4. Used with: A. Insulation attachment X XB Built-up membranesC. Single-ply membranes X X5. Material ~ HARDENED STEELSAE 1022. HEAT TREATED8. Co8l8d (yeslno) YES YES7. Coetlng Type TUfF-TITE . FL~CAR8ON POLYMER8. Shank ~pa SPIRAL THREAD SPIRAL THREADED9. Point ~pe PINCH. SELF-DRILLING SELF-DRILLING10. Method 01 Attachment THREADED THREADEO11. Dlametar, Length, f88I8nlng Range, Penetratlon- ======~=====l=====~=====l=====:=====l=====:======= ======~=====l=====~=====l=====:=====l=====:=======Column 1 Column 2 0.202 1 1/4 1/4 1 0.180 1 1/4 1/4 1Shank diameters Shank lengths 0.202 2 1 1 0.180 1 5/8 5/8 1available available 0.202 3 2 1 0.180 2 1/4 t 1/4 1(inches) (inches) 0.202 4 3 1 0.180 2 7/8 1 7/8 10.202 5 4 1 0.180 31/4 21/4 1Column 3 Column 4 0.202 6 5 1 0.180 3 3/4 2 3/4 1Fastening range. Minimum required 0.202 7 6 1 0.180 4 1/2 3 1/2 1maximum total thickness deck penetration 0.202 8 7 1 0.180 5 4 1(inches) (inches) 0.202 10 8 1 0.180 6 5 1- 0.202 12 10 1 0.180 7 6 10.202 14 12 1 0.180 8 7 10.202 16 14 1 0.200 10 9 10.200 12 11 10.200 14 13 112. Heed Shape RWNO WITH 13 PHILLIPS TRUSS RWND HUSHR~ 13 PHILLIPS13. Thickness Heed Dimensions (inches)0.103 0.110Diameter 0.425 0.43714. A Plates Required (yesino) YES YESB Available trom manufacturer (yes/no) YES YESCoIU;;;~ 11 I 3 ~;;;;~;E 3 ~~~~~~;;;E ~E; 2-7i8 ~~~~~~~EShape Dimension Column 2 Column M~risl(inches)16. Installation EquipmentScrew gun (optional/required)Installation tool with screw gun (optional/required)Special tool needed (optional/required)OtherHIGH-TORQUE SCREW GUN (REQUIRED)REQUIREDREQUIRED,17. Average Pullout Resistance (Ibs)(FM Tinius Olsen pullout resistance lests,3,000 PSI aged 28 days) 648 70018. Meets the FM Approval Requirements as aComponent 01 Cless I Concrete Rool Construction(yes/no) YES YES19. Accepted by the FotI_lng Codes FM FM. ICBO. UL. S8CCI20. Werrenly Avellable from Manufacturer (yesino) YES YES21. See Appendix II Checked XNA = not applicable456

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!