11.07.2015 Views

! j I I - National Roofing Contractors Association

! j I I - National Roofing Contractors Association

! j I I - National Roofing Contractors Association

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Built-up <strong>Roofing</strong>General information with test description and suggested values as specified in NBS BSS #55/1974Mineral Fiber Mfg. Corp.Owens-Corning Fiberglas1. No. of regional service locations:2. Licensed applicator agreement (yes/no): YES3. Kind of applicator training available: FIELD FIELD SEMINARS4. 5. Distribution Preformed accessories method (distributors available (yes/no): and/or direct): NO DISTRiBUTORS YES ' DIRECT6. Limitations/restrictions: SEE OCF BUR MANUAL7. For sales/technical information: STEVE FOSTER/ROBERT SIMPSONLOCAL OFFICE/LOCAL OFFICEB. Felts data: trade name (applicable ASTM standard): DURAPL Y IV (D3178-81 TYPE IV)PERNA PL Y-R (D2178-89 TYPE VI, TABLES 1 & 2)DURABASE (NONE)PERNA PLY NO_28 (D4601-86 TYPE II)POLYPLY (NONE)PERNA CAP (3909-81)PERNA PLY IV (D2178-89 TYPE IV, TABLES 1 & 2). PERNA PLY-6 (D2178-89 TYPE VI, TABLES 1 & 2)8. SpecIflC8tlon Number 43-GAW 43-GSW 43-GAC 44-GSC 52-PAW 52-PSW 52-PSt 52-PAt 23-TG 23-Tt 33-TS 33-IS 43-NG 33-IG23E-TG 23E-Tt 33E-TS 33E-IS 43E-NG 33E-IG1D. Hot and/or Cold Applied HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT11. Deck lYpe:A. Nailable X X X X XB Insulated X X X X X X X X XC Nonnallable X X X X12. Slope Requirements (range In inches): m-:-3 i72-=-6 m-:-3 i72-=-6 m-:-3 m-:-3 m-:-3 m-:-3 O":T -o-:-T -o-:-T -o-:-T O":T O":T13. Number of Pllea:A Total plies 4 4 3 4 3 3 2 2 2 3 3 3 4 3B Base sheet 1 1 1 1C Interply(ies) 3 3 3 4 2 2 2 2 2 2 3 3 3 3D. Cap sheet 114. 1YpeS of Felt:A Glassliber X - X X X X X X X X XB OrganicC AsbestosD. Polyester X X X XE Other15. Interply Adhesive:A Asphall X X X X X X X X X X X X X XB Moditied asphalt X X X X X XC. Coal tarD Elastomeric adhesive16. Surfeclng:AggregateA Gravel (lbs/It') 4 4 4 4 4 4 4B Slag (lbs./It') 3 3 3C Crushed rock (lbs.III')SmoothD Asphall X X X XE Coal tarF Emulsion/cutback X X X X X XG Aluminum coatingH Vinyl/vinyl coatingOtherI Mineral granulesJ Cap sheet XK Other17. Weight (approx. Ibs./ft2) Including piles:A Aggregate 6.0 2.0 6.0 2.0 5.0 2.0 2.0 6.0 5.50 6.0 5.50B Smooth 1.50 1.50C Cap sheet 2.018. Restricted Regions (reler to mlr.'s literatur.) - - - - - - - - rr;-iTJ NiiNE NiiNE rr;-iTJ NiiNE NiiNE19. Year of Firat Commercial Use 1976 1976 1976 1976 1982 1982 1982 1982 1965 1965 1965 1965 1965 19652D. Test Results (per NBS BSS 1/55) - - - - - - - - - - - - - --MD = Machine DirectionXD ~ Cross Machine DirectionA. Tensile Strength (~2DO Ib/ln @ ODf)-MD 343 343 293 382 166 166 226 238 283 238-XD 257 257 241 333 198 198 224 321 320 321B. Thermal ~ (~ ~4Ox1O4/Df@O"F ., -~D ~ ~ "T8T --zfT - - - - ~ ~ VT WT ~ WT-XD 27.9 27.9 16.8 21.3 24.0 24.0 13.6 12.9 25.2 12.9c. The,",.1 Base Shock (Not ~1DODf)-MD ~ ~ ~ ~ - - - - ~ ~ ~ ~ ~ ~21. See M.lIGrene Appendix-XD 523 523 840 883 645 645 645 1,294 616 1,294If checked - - - - - - - - -x- -x- -x- -x- -x- -x-""" -~... 34

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!