Modified Bitumen Part 2: Test ResultsTest Description and suggested values as specified in CGSB Standard 37-GP-56M1. Company Name GARLAND GARLAND GARLAND GARLAND GARLANDCO INC, CO INC, CO INC, CO INC, CO INC,THE THE THE THE THE2. Product Name GARLAPLY GARLAPLY II STRESSPLY STRESSPLY STRESSPLY FRMS3. ~ 4. CIaaa 5. Grade TYPE CLASS GRADE TYPE CLASS GRADE TYPE CLASS GRADE TYPE CLASS GRADE TYPE CLASS GRADE1A,2A C 1 IA A 1 - C 1&2 IA A 1 - - -6. Braaklng Strangth: Grade 1 min. 66 Ibf (MD/XD) NO - XC - NO - XD - NO - XD - NO - XD - NO - XD -7. Ultimate Elongation:Grade 2 min. 176 Ibf (MD/XD) NO NA XD NA NO NA XD NA NO - XD - NO NA XC NA NO - XC -Grade 1 min. 4.0% (MD/XD) NO - XC - NO - XD - NOXCNO - XC -Grade 2 min. 8.0% (MD/XD) NO NA XD NA NO NA XD NA NO - XD - NO NA XD NANONO -XDXD -8. Load Strain Product [Braak Strangth (Ib!)x Ultimate Elongation (%)):Grade 1 if breaking strength is not met, 4362 - - - - -Grade 1 if breaking strength is met, 661 - - - - -Grade 2 min. 3305 NA NA - "NA -9. Water Realatance not more than 10g dimensionmoreChg not - - - - -than x1.0%(MD/XD) NO - XD - NO - XD - NO - XD - NO - XD - NO - XC-10. Low Tamp Flexibility: ~pa 1 @ -22Of (pass/fail) - - - - -~pa 2 @ x14Of (pass/fail) - NA - NA -11. Water Vapor bn.ml8Slon max. 1.Ogim2 x 24 hr. - - - - -12. Thermal less than Stability: 1.0mmlin ~pe 1, CIa8S B Only NA NA NA NA -13. Dynamic Impact (Puncturing). Water Tightness:Grade 1 after impact of 18 ft Ibf (pass/fail) - - - - -Grade 2 after impact of 3.6 ft Ibf (pass/fail) NA NA - NA -14. Static Puncturing: ~pa 1 Water Tightness after 1 hr.@55Ibf(pass/fail) - - - - -15. Lap Joint Strangth (5-day conditioning)Grade 1 min 66 Ibf (MD/XD) NO - XD - NO - XD - NO - XC - NO - XD - NO - XD -Grade 2 min 176 Ibf (MD/XD) NO NA XD NA NO NA XD NA NO - XD - NO NA XD NA NO - XD -Grade 1&2 Pass Water Tightness Test (pass/fail) - - - - -Grade 1 min 66lbf (MD/XD) NO - XD - NO - XD - NO XD NO - XD - NO XD Grade 2 min 176 Ibf (MD/XD) NO NA XD NA NO NA XD NA NO - XD - NO NA XD NA NO - XD -Grade 1&2 Pass Water Tightness Test (pass/fail) - - - - -16. Lap Joint St~ngth (Immersion@ 5DOC for 5 days)17. Lap Joint St~ngth (Immersion @ SO'C, 5 Days +Freeze Thaw) NO - XD - NO - XD - NO XD NO - XD - NO Grade 21 min 66 176 Ibf Ibf (MD/XD) NO NA XD NA NO NA XD NA NO - XD - NO NA XC NA NO - XD-Grade 1&2 Pass Water Tightness Test (pass/fail) - - Class A only max. 2g loss NA - NA - -18. Granule Embedment:19. Acceleratad Weathering: ~pe 1 OnlyNo Cracking or Blistering (pass/fail) - - PASS - -Retain QO% of Breaking Strength (*6) (MD/XD) NO XD NO XD NO - XD NO XC NO XD Retain 90% of Elongation at Break (*7) (MD/XD) NO - XD - NO - XD - NO - XD - NO - XC - NO - XD -20. Crack Bridging Capability (No Cracking, Splitting)(pass/fail) - - - - -21. See Membrana Appendix if checked22. Lagend: NA = not applicable;MD = machine dl~ctlon;XD = cross machine dl~ctlon;blank line. = .ppllcable data notaupplledby manufactu~rFrom CGSB Standard 37-GP-56M~pa: 1. For exposed roofing application1.a. Fuily adhered1.b. Partiaily adheredI~pe: 2. For covered roofing application2.a. Fuily adhered2.b. Partlaily adhered2.c. Loose laidClass:A. Granule surlacedB. Metailic surlacedC. Plain surlacedGrade: 1. Standard service2. Heavy dutY service.82 ',",.. .- ._~

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!