11.07.2015 Views

! j I I - National Roofing Contractors Association

! j I I - National Roofing Contractors Association

! j I I - National Roofing Contractors Association

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Metal Roof Panels1. COMPANY NAME Butler Narofecturing C"","ny Butler Narofacturing C"","ny2. PRODUCTNAME CMR-24 Roof System-Butlerib II3. Architectural Appllcatlona (yea/no) no noStructural Applications (yeaino) yes yes4. PANEL CONFIGURATION4A. Panel Description Dooble Lock Standing SeMI Dooble Lock Standing SeMI48. Panel Materials, Thicknesses, and Finishes Thicknesses Finished Dr Unfinished Thicknesses Finished Dr Unfinished================ ============================================= ==============================galvanized steel (ga,) 22,24,26 Kynar SOD, silicon polyester 24,26,2/1 Kynar SOD, silicon polyesterstainless steel (ga.)galvalume (ga.) 22,24,26 Unfinished 24,26,28 Unfinishedaluminized steel (ga.) 24,26 Unfinished 24,26,28 Unfinishedaluminum (In.)anodized aluminum (In.)copper (oz.)terne metal (ga.)zinc (ga)4C Maximum Length (II.) 60 404D. Panel Widths (In.) 24 365, SYSTEMS REQUIREMENTSSA Minimum Slope (in. per II) 1/4: 12 1/4: 1258. SolId Decking (required, optional, Dr not uaad)requl rednot used5C. Underlayment (type Dr NA)NA6. PANEL PROFILE Vertical Trape- Batten Other Otherleg zoidal, I X I X7. SEAM PROCESSING, HEIGHT, AND SEALANT Height(s) He;ght(s)(ins.)(ins.)Seam overlappedProcessingcrimped (45 degree) X 1 1/2 Froll formed (180 degrees) X 2 3/4 Fdouble roll formed (2 180 degrees)roll and locksnap-on capsnap togetherB. FASTENING METHOD8A. Through fastened, exposed X88. Through fastened, concealed8C. Clip, concealedfixed clipslip clipmoveable clip (designed allowable movement, Ins.) 2 1/2g. Speclelty Applicationscurvedtaperedother10. Manufacturer_uct Data Engineering Year of Licensed Kind of Engineering Yeer of Licensed Kind ofSl4'pDrt First Applicator Applicator Sl4'pDrt First Applicator ApplicatorAvailable C~rcial Agre_nt Training Available C~rcial Agre_nt Training(yes/no) Use (yes/no) Available (yes/no) Use (yes/no) Availableyes 1988 yes seminars, yes 1945 yes seminars,on siteon-siteFor sales informatIon, contact: 816-968-3322 816-968-3322For technical inlormetlon, contact: 816-968-3322 816-968-332211. ASTM E331 Watar Infiltration Test Resull8 none none12. ASTM E283 Air Infiltration Teat Rasulta none none13. FM-ULWlndUpliftRatlngsforAnySpeclflcatlon UL-90, FN-I-90 UL-9014. See Appendix If Checked XNA = not appl-

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!