11.07.2015 Views

! j I I - National Roofing Contractors Association

! j I I - National Roofing Contractors Association

! j I I - National Roofing Contractors Association

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

"'C 426Roof Fasteners: Steel Decks1. Company NemeTRU-FAST CORPORATIONTRU-FAST ~~TI!JI2. PIoduc1 Neme DP ULTRA STAINLESS STEEL TP3. Coun1ry of Menuf8c1ure U.S. U.S.-4. Ueed with:A. Insulation attachment X XB Built-up membranes X XC Single-ply membranes X X5. Meterlel ~pe STAINLESS STEEL (TRIMRITE ALLDY 15-42010) CARBON STEEL C-10226. Co8ted (yesino) NO YES7. Co8llng Type NA TRU-KOTE PC-3 (FLUOROCARBON PAINT)6. Shenk ~ THREADED THREADED9. Polnt~pe DOJ9LE FLUTE SELF-DRILLING GIMLET10. Method of AlI8Chment THREADED THREADED11. Dlemeter, Length, _nlng Renee, Penetmllon 1 I 2 I 3 I 4 1 I 2 I 3 I 4================================================== ==================================================Column 1 Column 2 0.160 1 5/8 1 1/8 1/2 0.150 1 5/8 1 1/8 1/2Shank diameters Shank lengths 0.160 21/4 1 3/4 1/2 0.150 2 1/4 1 3/4 1/2available available 0.160 2 7/8 2 3/8 1/2 0.150 2 7/8 2 3/8 1/2(inches) (inches) 0.160 3 3/4 3 1/4 1/2 0.150 3 3/4 3 1/4 1/20.160 41/2 4 1/2 0.150 41/2 4 1/2Column 3 Column 4 0.160 5 4 1/2 1/2 0.150 5 4 1/2 1/2Fastenong range. RequIred 0.160 6 5 1/2 1/2 0.150 6 5 1/2 1/2maxImum total thIckness deck penetratIon 0.160 7 6 1/2 1/2(inches) (inches) 0.160 8 7 1/2 1/20.160 10 91/2 1/20.160 12 11 1/2 1/212. Heed Shepe 110 TRUSS PHILLIPS MODIFIED PHILLIPS 1213. Heed Dimensions (inches)Thickness 0.105 0.110Diameter 0.440 0.39014. PletesA Required (yes/no)B Available from manufacturer (yes/no)YESYES15. Plete Shepe, Dimensions, end Mete"el - ========~=======l=======~=======l=======~========= ========~=======l=======~=======l=======~=========Column 1I Column 2 I Column 3 ROOND 2 GALVALUME ROOND 2 GALVALUMEShape Dimension Material ROOND 3 GALVALUME ROOND 3 GALVALUME(inches) ROOND 3 PLASTIC ROOND 3 PLASTIC16. Instellellon EquipmentScrew gun (optional/required) REQUIRED REQUIREDInstallation tool with screw gun (optional/required)OPT IONALOPT (!JIALSpecial tool needed (optional/required)Other17. Avemge Pullout Realstence (Ibs)(FM Tinius Olsen pullout resistance tests)18 gauge 72020 gauge 620 61022 gauge 473 49418. Meets the FM Approval Requlremente e. eComponent of Cle.. I Steel Roof Deck (yes/no) YES YES19. Pease. FM text procedure 4470 lor corrosionre.l.tence (yes/no)20. Accepted by the following Code. FM, METRO-DADE COONTYYESFM, METRO-DADE COUNTY21. Werranty Avell_le from Menuf8cturer (yesino) YES YES22. See Appendix If C-NA = not eppllc8ble

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!