11.07.2015 Views

! j I I - National Roofing Contractors Association

! j I I - National Roofing Contractors Association

! j I I - National Roofing Contractors Association

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Roof Fasteners: Steel Decks1. Company Nama ITII BUILDEX ITII BUILDEX2. Product Name ROOFGRIP S-12 GRIPDEK3. Country of Manulactu18 U.S. U.S./JAPAN4. Uoad with:A Insulation attachment X XB. Built-up membranes X XC Single-ply membranes X X5. Material ~pe HARDENED CARB(»I STEEL HARDENED CARBON STEEL6. Coated (yes/no) YES YES.7. Coating Type CLIMASEAL SPEXB. Shank~pe STANDARD THREADSTANDARD THREAD9. Point ~pe SELF-DRILLING GIMLET10. Mathod of Attachmant THREADED THREADED11. Diameter, Length, Faatenlng Range, Penatratlon 1 I 2 I 3 I 4 1 I 2 I 3 I 4Column 1 Column 2 0.189 27/8 23/8 1/2 0.189 1 5/8 1 1/8 1/2Shank diameters Shank lengths 0.189 33/4 3 1/4 1/2 0.189 2 1/4 13/4 1/2available available 0.189 4 3/8 3 7/8 1/2 0.189 2 7/8 2 3/8 1/2(inches) (inches) 0.189 5 4 1/2 1/2 0.189 3 3/4 3 1/4 1/20.189 6 51/2 1/2 0.189 43/8 37/8 1/2Column 3 Column 4 0.189 5 4 1/2 1/2Fastening range, Requirad 0.189 6 5 1/2 1/2maximum total thickness deck penetration(inChes)(inches),12. Head Shape '2 PHILLIPS PAN HEAD '2 PHILLIPS PAN HEAD13. Head Dlmanalona (inches)Thickness 0.115 0.115Diameter 0.392 0.39214. PlatesA Required (yes/no) YES YESB Available from manufacturer (yesino) YES YES15. Plata Shape, Dimensions, and Matarial 1 I 2 I 3 1 I 2 I 3Column Shape 1I Column 2DimensionI Column 3Material~~~~;EROOND3-;-33~~;~;;;;-~~EE~--- ~;;;;;;EPOLYOLEFIN ROOND3-;-33~~;~~~-~~EE~---POLYOLEFIN(inches) ROOND ROONDGEAR LOCKROOND32POLYOLEFINCARBON STEELGEAR LOCKROOND32POLYOLEFINCARBON STEEL16. Instellotlon EquipmentScrew gun (optional/required) REWIRED REQUIREDInstallation tool with screw gun (optionaVrequlred)CN'TIONAL (ACCUDRIVE XL)CN'TIONAL (ACCUORIVE XL)Special tool needed (optionaVrequired)Other17. Average Pullout Reolotance (Ibs.)(FM Tinius Olsen pullout resistance tests)1B gaugeNA20 gauge NA 42022 gauge NA 36018. Meato the FM Approval Requlremento - aComponent of Clas I Steel Roof Deck (yesino) NO YES19. Pe818S FM text pnICedU18 4470 lor corroeionreolstance (yes/no) YES YES20. Accepted by the Following Codeo21. Wamnty Available from ManufactU18r (yes/no) YES YES22. See Appendix If Checbd XNA = not applicable420

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!