11.07.2015 Views

! j I I - National Roofing Contractors Association

! j I I - National Roofing Contractors Association

! j I I - National Roofing Contractors Association

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

FiberboardRoof Board Insulation(Homogeneous Only)1. Company GAF BUILDING GEORGIA HUEBERT HUEBERT KOPPERS KOPPERS TEMPLEMATERIALS PACIFIC FIBERBOARD FIBERBOARD INDUSTRIES INDUSTRIES INLANDCORP CORP INC INC INC INC2. State NJ VA HO HO PA PA TX3. P~uctll-8de Name GAFTEMP High Sturdi -Top HF8 R.I. Plus K~-R K~-R Hi9h Fiber-Base HDDensity Fbrbrd Regular Fbrbrd Density Fbrbrd4. Surface lIeatment: Top Surface Surface Asphal t None None Surface Surface Asphal tTreat~t EnaJlsion Treat~t Treat~nt Coated orUncoated~om Surface None None None None None None Asphal tCoated orUncoated5. Available aa Tapered Material ND NO NO NO NO NO NO6. "er FI..t Used in Commerciel Rooltng Systema 1928 1986 1961 1988 1928 1928 19827. Meats Applicable Standard Specifications LLLI5358 C208-72 C208-72 C208-72 LLLI5358 LLLI5358 LLL-I-5358ClsE,C208 LLLI5358,ClsE LLLI5358,ClsC LLLI535B,ClsE ASTM C208 ASTM C208 Cls E, Style 1ANSI-194.1 PS57-73 ASTM C2D88. Common Avelleble Sims (Contact mlr for othar sizes8.1 2' x 4' and special orders) X X X8.2 3' x 4'8.3 4' x 4' X X X X X X X8.4 4' x 8' X X X X X X X85 Other9 . Common Avalleble Thicknesses ICont~ 'hockno ml, to, ) otho,S_,C_R__' 0.5 0.5 0.5 0.5 0.5 0.5 0.591 Thickness; In Inches 7 MAX 5 to 10 7 MAX 7 MAXWater Absorbt (per ASTM C-209 or other); % by vol 14 7 14 14Transverse Strength (per ASTM C-203 or other); psiThermal Conductance (C): ~::; 0.77 0.80 0.72 0.80 0- 72 0.77 0.758Thermal Aesistance(A) :;~::; 1.3 1.25 1.39 1.25 1.39 1.3 1.32Weight; Ibs/ft' 0.80 0.65 0.75 0.90 0.70 0.8092 Thickness;,in inches 1.0 0.75 1.0 1.0 1.0Water Absorb! (per ASTM C-209 or other); % by vol 5 to 10 7Transverse Strength (per ASTM C-203 or ~her); psi 12Thermal Conductance (C) @ 4OOf@ 75Of 0.4D 0.48 0.36 0.40 0.40Thermal Aesistance (A) @ 4OOf@ 75Of 2.5 2.08 2.78 2.5 2.50Weight; Ibs/lt' 1.6 1.1 1.4 1.6 1.59.3 Thickness; in inches 1.5 1.0 1.5 1.5 1.5Water Absorbt (per ASTM C-209 or other); % by vol 5 to 10 7Transverse Strength (per ASTM C-203 or ~her); psi 14Thermal Conductance (C) @ 40°F@ 75Of 0.26 0.36 0.24 0.26 0.26Thermal Aesistance (A) @ 40°F@ 75Of 3.8 2.78 4.17 3.8 3.80Weight; Ibs/lt' 2.4 1.5 2.1 2.4 2.2594 Thickness; in inches 1.5 2.0 2.0Water Absorbt (per ASTM C-209 or ~her); % by vol 7Transverse Strength (per ASTM C-2Q3 or other); psiThermal Conductance (C) @ 4OOf@ 75Of 0.24 0.18 0.20Thermal Aesistance (A) @ 4OOf@ 75Of 4.17 5.56 5.0Weight; Ibs/lt' 2.3 2.8 3.095 Thickness; in inches 2.0Water Absorbt (per ASTM C-209 or other); % by volTransverse Strength (per ASTM C-203 or ~her); psiThermal Conductance (C) @ 40Of@ 75Of 0.19Thermal Aesistance (A) @ 40Of@ 75°F 5.26Weight; Ibs/lt' 3.010. Estimated ~ of Thermal Value Retention @ 1 year 100 100 100 100 100 100(Assuming a continuous mean temperature 5 yea.. 100 100 100 100 100 100differential and constant moisture content) 10 yea.. 100 100 100 100 100 10011. UL "p.' Dealgn Numbers; Building Code AgencyApproval Numbe..; ICBO, BOCA, SacCI (othe..)12. Llmltatlona and/or Restrlctlona See Appendix See Appendix See Appendix See Appendix13. Sea Inaulatlon Appendix II checked X X X XNote 1: FM Windstorm and Fire Aatings are often important when considering the selection of aroofing insulation material To determine the availability of a rating and approved attachmentmethods for various materials, refer to specific listings published in the FM Approval GuideNote 2: NA = Not applicable376

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!