11.07.2015 Views

! j I I - National Roofing Contractors Association

! j I I - National Roofing Contractors Association

! j I I - National Roofing Contractors Association

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

.51 Plate Shape, Dimensions, and Material =~=!=~=!=~= =~=!=-=.~=-_! =-~Roof Fasteners: Concrete Decks1. Company Name CARLISLE SYNTEC SYSTEMS CARLISLE SYNTEC SYSTEMS2. Product Name HP CONCRETE SECURSPIKEHP CONCRETE SECURSPIKE (CONTINUED)3. Country of Manufacture U. S.4. Used with:A Insulation attachmentB Built-up membranasC Single-ply membranesXXX5. Material ~pe HARDENED STEEL6. Coatad (yes/no) YES7. Coating Type PERMASEAL FLUOROCARBON8.'Shank ~pe9. Point ~pe NA10. Method of Attachment SHANK C~PRESSION11. Diameter, t.ngth, Fastening Range, Penetration 1 I 2 I 3 I 4 1 I 2 I 3 I 4================================================== ==================================================Column 1 Column 2 0.24 1 1/2 1/4 1 1/4 0.24 13 1/2 121/4 1 1/4Shank diameters Shank lengths 0.24 2 3/4 1 1/4 0.24 14 12 3/4 1 1/4available available 0.24 2 1/2 1 1/4 1 1/4 0.24 14 1/2 13 1/4 1 1/4(inches) (inches) 0.24 3 1 3/4 1 1/4 0.24 15 13 3/4 1 1/40.24 31/2 21/4 1 1/4 0.24 151/2 141/4 1 1/4Column 3 Column 4 0.24 4 2 3/4 1 1/4 0.24 16 14 3/4 1 1/4Fastening range, Minimum required 0.24 4 1/2 3 1/4 1 1/4maximum total thickness deck penetration 0.24 5 3 3/4 1 1/4(inches) (inches) 0.24 5 1/2 4 1/4 1 1/40.24 6 43/4 1 1/40.24 61/2 51/4 1 1/40.24 7 53/4 1 1/40.24 71/2 61/4 1 1/40.24 8 63/4 1 1/40.24 81/2 71/4 1 1/40.24 9 73/4 1 1/40.24 91/2 81/4 1 1/40.24 10 83/4 1 1/40.24 101/2 91/4 1 1/40.24 11 93/4 1 1/40.24 11 1/2 101/4 1 1/4~ 0.24 12 103/4 1 1/40.24 121/2 11 1/4 1 1/40.24 13 11 3/4 1 1/412. Head Shape RWND13. Head Dimensions (inches)Thickness 0.10Diameter 0.422.14. PlatesA Required (yes/no)B Available from manufacturer (yes/no)YESYESColumn 1Shape Dimension Column 2 Column Material 3 RWNDED SQUARE WITH CORNERS 3 1/4 GALVALUME -I I(inches)R~NO 2 GALVALUME16. Instellatlon EquipmentScrew gun (optional/required)Installation tool with screw gun (optional/required)Speciai tool needed (optional/required)OtherSDS SPIKE DRIVER (OPTIONAL)HAMMER (REQUIRED)17. Average Pullout Resistance (Ibs)(FM Tinius Olsen pullout resistance tests,3,000 PSI aged 28 days)18. Meets the FM Approval Requirements as aComponent of Claas I Concrete Roof Construction(yes/no)YES19. Acceptad by the following Codes FM20. Warranty Available from Manufacturer (yea/no) YES21. See Appendix If Chec-NA = not applicable452

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!