11.07.2015 Views

! j I I - National Roofing Contractors Association

! j I I - National Roofing Contractors Association

! j I I - National Roofing Contractors Association

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

SeamProce88lng~Metal Roof Panels1. COMPANY NAME Al x Building Speci8lty Oivisi~ Al x Building Speci8lty Oivisi~2. PRODUCT NAME Sup-R-Se- Sl im Se-3. A~ltectur81 Appllcatlon8 (ye8/no) yea yeaStructur81 Applications (ye8ino) no yes4. PANEL CONFIGURATION4A. Pan81 Description Snap-~ St~ing Se- Integr8l St~ing Se-48. Panel Msterl8ls. Thicknesses. 8nd Finishes Thicknesses Finished or Unfinished Thicknesses Finished or Unfinished================ ============================================= ==============================galvanized steel (g8.) 24 Kyner 500 24 Kyner 500stalnle88 steel (ga.)galvalume (ga.) 24 Kyner 500, \61'8inted 24 Kyner 500, \61'8intedaluminized steel (g8.)aluminum (In) 0.032,0.040 Kyner 500 0.032,0.040 Kyner SOOanodized aluminum (In.)copper (oz) 16,20terne metal (g8.)zinc (ga.)4c. M8xlmum Langth (If.) 40 4040. Panel Widths (In.) 14,18 12,165. SYSTEMS REQUIREMENTSISA. Minimum Slope (In. per It.) 3:12 1:1258. Solid Decking (required, optlon81, or not u88d)requiredoptional5C. Underleymant (type or NA) 30-lb. fel t 30-lb. fel t6. PANEL PROFILE Vertical Trepe- B8tten Other Vertic8l Tr8pe- B8tten Otherleg zoidal leg zoidalX I I X I I7. SEAM PROCESSING, HEIGHT, AND SEALANT Height(s) Se~ Sealant Height(s) Se~ Sealant(ins.) F=factoryapplied (ins.) F=factoryappliedE=field applied E=field appliedN=noneN=noneoverlappedcrimped (45 degree)roll formed (t60 degrees)double roll formed (2 180 degrees)roll and locksnap-on cap X 1 1/2 Nsn8p together X 1 1/2 Fe. FASTENING METHOD8A. Through f8stened, exposed88 Through fastened. concealed8C. Clip, concealedIIxed clipslip clip X Xmoveable clip (designed allowable movement, Ins.)g. Specl81ty ApplicationsiI Avai"'" ,.curvedtapered X Xother10. M8nufacturer/Product Dsl8 Engineering Year of Licensed Kind of Engineering Year of Licensed Kind ofS~rt First Applicator Applicator S~rt First Applicator Applicatortable Commercial Agr~t Training Avai table Commercial Agr~t Training~~~~~~~--- ~~~ ~~~~~~~_. ~~~~~~~~~ ~~~~~~~--- ~~~ ~~~~~~~-- ~~~~~~~~~yes 1985 no yes 1987 noFor uleslnlorm8tlon, conl8ct: o. Pickens o. PickensFortechnlc81lnformatlon, conl8ct: L. Morris L. Norr;s11. ASTM E33t W8ler Inliitration Test Reaui18 none no penetrati~ under S-gal.-per-hour spray st10 psf pressure differential12. ASTM E283 Air Inliitration Test Results none maxi of 0.09 cu. ft. per minute per sq. ft.with 1.57 psf pressure differential13. FM-UL Wind Uplift R8Itngsior Any Specification none UL-9014, See Appendix if Checked X XNA = not applicable

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!