11.07.2015 Views

! j I I - National Roofing Contractors Association

! j I I - National Roofing Contractors Association

! j I I - National Roofing Contractors Association

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

.51 Plate Shape, Dimensions, and Material = ~! ~ ! ~= ~ ! ~ ! ~Roof Fasteners: Concrete Decks1. Company Name HILTI INC. ITW BUILDEX2. ProduC1 Name HILTI FASTENERS ALL-PURPOSESTRIKER3. Country of M8nu!aC1ure U.S. CANADA4. Used with:A. Insulation aUBchment X XB Built-up membranes X XC Single-ply membranes X X5. Materlal~pe CARBON STEEL (1022) & STAINLESS STEELHARDENED CARBON STEELe. Coated (yesino) YES YES.7. Coating Type TAFT COAT (FLlKIROPOLYMER PAINT)HOT-DIPPED GALVANIZED8. Shank lYpe THREADED SPIRAL9. Point ~pe SELF-DRILLING NAIL10. Mathod of Attachment THREADEO FRICTION11. Diameter, ~ngth, Faatenlng Range, Panetratlon ======~=====l=====~=====l=====~=====l=====:======= ======~=====l=====~=====l=====~=====l=====:=======Column 1 Column 2 0.187 1 1/4 3/4 1/2 0.210 1 1/8 1/8 1Shank diameters Shank lengths 0.187 1 5/8 1 1/8 1/2 0.210 1 1/2 1/2 1available available 0.187 1 3/4 1 1/2 1/2 0.212 2 1 1(inches) (inches) 0.187 21/4 13/4 1/2 0.210 21/2 1 1/2 10.187 23/4 21/4 1/2 0.210 3 2 1Column 3 Column 4 0.187 25/8 21/8 1/2 0.210 31/2 21/2 1Fastening range, Minimum required 0.187 3 1/4 2 3/4 1/2 0.210 4 3 1maximum total thickness deck penetration 0.187 3 3/4 3 1/4 1/2 0.210 4 1/2 3 1/2 1(inches) (inches) 0.187 4 1/4 3 3/4 1/2 0.210 5 4 10.187 4 1/2 4 1/2 0.210 51/2 41/2 10.187 5 41/2 1/2 0.210 6 5 10.187 6 5 1/2 1/2 0.210 7 6 10.187 7 61/2 1/2 0.223 8 7 10.187 8 71/2 1/2 0.223 9 8 10.187 10 91/2 1/20.187 12 11 1/2 1/212. Head Shape '10 TRUSS, PHILLIPS 13 NAIL TYPE13.ThicknessHead Dimensions (inchas)0.111 0.100Diameter 0.437 0.40014. PlatesA Required (yesino) YES YESB. Available from manufacturer (yeslno) YES YESColumn 1I Column 2 I Column 3 ;~~~ 2 ~90-~~~V~~~~~~-- ~~~~;~ 3-;-3 ~~;;;;;;-~~~~~---Shape Dimension Meterial R().JNO 3 G90 GALVANIZED R().JNO 3 POLYOLEFIN(inches) R().JND 3 CO-POLY PLASTIC R().JNO 2 CARBON STEELR().JND 2 GALFANR().JNO 3 GAL FAN16. InstallatIon EquipmentScrew gun (optional/required)REQUIREDInstallation tool with screw gun (optional/required)Special tool needed (optional/required)Other DRILL BIT CARBIDE (REQUIRED) DRILL 81T WITH ROTARY HAMMER & HAMMER (REQUIRED)17. Average Pullout Resistance (Ibs.)(FM Tinius Olsen pullout resistance tests.3.000 PSI aged 28 days) 799 1,10018. Meeta the FM Approval Requirements 88 aComponent of CI888 I Concrete Roof ConstNC1lon(yes/no) YES YES19. Acceptad by tha following Codes FM, BOCA, IC80, METRO. -DADE C().JNTYFM, UL, METRO-DADE C().JNTY20. Warranty Available from Manu!aC1urer (yes/no) YES YES21. See Appendix If CheckedNA = not applicable,,;:c458

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!