11.07.2015 Views

! j I I - National Roofing Contractors Association

! j I I - National Roofing Contractors Association

! j I I - National Roofing Contractors Association

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Ii 6.I ColumniRoof Fasteners: Wood Decks1. Company Nama OLYMPIC MANUFACTURING GRWP OLYMPIC MANUFACTURING GRWP12. Product Name OLYMPIC FASTENER '10-16 OLYMPIC FASTENER '12-11 (C.STEEL)3. Country of Manufacture U.s. U.S.4. Uaad with:A. Insulation attachment X XB Built-up membranes X XC Single-ply membranes X X5. MatertallYpe HAROENEO CARBON STEEL HARDENED CARBON STEELCoated (yeoino) YES YESi .'7. Coating Type CR-10 FLUOROCARBON CR-10 FLUOROCARBON8. Shank lYpe THREADED THREADEO9. PolntlYpe GIMLET PINCH, SELF-DRILLING; GIMLET, OR TAPEX1D. Method 01 Attechment THREADED THREADED: 11. Diameter, Length, Faatenlng Range, Penetrellon 1 I 2 I 3 I 10 I 5 1 I 2 I 3 I 10 I 5! ================================================== ==================================================1 Column 2 0.155 1 5/8 1 1/8 1/2 1 0.172 1 5/8 1 1/8 1/2 1Shank diamaters Shank lengths 0.155 2 1/10 1 3/10 1/2 1 D.172 2 1/10 1 3/10 1/2 1available available 0.155 2 7/8 2 3/8 1/2 1 0.172 2 7/8 2 3/8 1/2 1(inches) (inches) 0.155 3 1/10 2 3/10 1/2 1 0.172 3 1/10 2 3/10 1/2 1Col 3 Col 4 0.155 33/10 31/10 1/2 1 0.1n 33/10 31/2 1/2 1umn umn 0.155 10 1/2 10 1/2 1 0.1n 10 1/2 10 1/2 1Fastemng ran.ge, RequIred deck 0.155 5 101/2 1/2 1 0.172 5 101/2 1/2 1maxImum total thIckness penatratlon, plywood 0.155 6 5 1/2 1/2 1 0.172 6 5 1/2 1/2 1(Inches) (Inches) 0.172 7 6 1/2 1/2 1Column 5 0.172 8 71/2 1/2 1Requireddeckpenatration,wood(inches),-12. Heed Shape RWND BINDING '2 PHILLIPS RWND TRUSS, 1"5 PHILLIPS13. Head Dlmenalona (inches)Thickness 0.108 0.110Diameter 0.390 0.103514. PlatesA Required (yes/no) YES YESB Available from manufacturer (yes/no) YES YES15. Plate Shape, Dlmenalons, and M8Iertel- 1 I 2 I 3 1 I 2 I 3==c:-i lg:~~~s~~ I ~=~13 =======:~~~=========~================:~~~~~:===== =======:~~~=========~================:~~~~~:=====(Inches) RWND 2 STAINLESS STEEL RWND 2 STAINLESS STEELRWND 3 STEEL RCXJND 3 STEELRWND 3 PLASTIC RCXJND 3 PLASTICRCXJND 3 STAINLESS STEEL RCXJND 3 STAINLESS STEELRCXJND 31/2 STEEL RCXJND 3 1/2 STEEL16. Instellallon Screw gun (optional/required) EquipmentREQUIRED REQUIREDInstallation tool with screw gun (optional/required) CH'T IONAL CH'T II»IALSpecial tool needed (optional/required)Other17. Average Pullout Resistance (Ibs)(FM Tinius tests)Olsen pullout resistance3/4-inch plywood 510 5312-inch pine plank 6810 7351B. Meets the FM Approval Requlrementa as aComponent of Class I Wood Roof (yes/no) YES YES19. Accepted by the following Codes FM, UL, ICBO, METRO.-DADE CWNTY FM, UL. ICBO. METRO.-DADE CWNTY2D. Warranty Available fnlm Manulacturar (yesino) YES YESI, 21. See Appendix 11 Chec- X XNA= not applicable.Co 444~-

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!