11.07.2015 Views

! j I I - National Roofing Contractors Association

! j I I - National Roofing Contractors Association

! j I I - National Roofing Contractors Association

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Roof Fasteners: Concrete Decks1. Company NameTHE RAWLPLUG CIJ4PANY INC.THE RAWLPLUG CC»4PANY INC.2. Product Name RAWL HEAVY DUTY '15 SCREW SPIKE3. Country of Manufacture U.S. U.S.4. U88d with:A Insulation attachment X XB. Built-up membranes X XC. Single-ply membranes X X5. Meterlal ~pe HARDENED STEELHARDENED STEEL & STAINLESS STEEL6. Coated (yes/no) YES YES7. Coating Type PERMASEAL PERMASEAL FLUDROCAR~ (HARDENED STEEL)8. Shank ~ SPIRAL THREAD9. PoInt~pe PUNCH, SELF-DRILLING NA10. Method of AlI8chment THREADED SHANK CC»4PRESSIC*11. Dlemeter, Length, F_nlng Renge, Penetration ======~=====l=====~=====l=====~=====l=====~============~=====l=====~=====l=====~=====l=====~=======Column 1 Column 2 0.205 1 1/4 1/4 1 0.24 1 1/2 1/4 1 1/4Shank diameters Shank lengths 0.205 2 1 1 0.24 2 3/4 1 1/4available available 0.205 3 2 1 0.24 2 1/2 1 1/4 1 1/4(inches) (inches) 0.205 4 3 1 0.24 3 1 3/4 1 1/40.205 5 4 1 0.24 31/2 21/4 1 1/4Column 3 Column 4 0.205 6 5 1 0.24 4 2 3/4 1 1/4Fastening range, Minimum required 0.205 7 6 1 0.24 4 1/2 3 1/4 1 1/4maximum total thickness deck penetration 0.205 8 7 1 0.24 5 3 3/4 1 1/4(inches) (inches) 0.205 10 9 1 0.24 5 1/2 4 1/4 1 1/40.205 12 11 1 0.24 6 43/4 1 1/40.205 14 13 1 0.24 61/2 5 1/4 1 1/40.205 16 15 1 0.24 7 53/4 1 1/40.24 71/2 61/4 1 1/40.24 8 63/4 1 1/40.24 81/2 71/4 1 1/40.24 9 73/4 1 1/40.24 91/2 81/4 1 1/40.24 10 83/4 1 1/40.24 101/2 91/4 1 1/40.24 11 103/4 1 1/40.24 11 1/2 101/4 1 1/4,. 0.24 12 113/4 1 1/40.24 121/2 11 1/4 1 1/40.24 13 123/4 1 1/412. Head Shape ROOND TRUSS, 13 PHILLIPS RECE5SROOND13. Head DimensionsThickness(inches)0.112 0.10Diameter 0.435 0.42214. PlatesA Required (yes/no) YES YESB Available from manufacturer (yes/no) YE5 YES15. Plate Column Shape, 1Dimensions, and Meterial ~ ! ~ ! ~ ~ ! ~ ! ~Shape Dimension Column 2 Column Material 3 -;~~~-;~;;~~ ROOND 32 ~~~~;~~~ GALVALUME ---;~~~-;;;;~~ ROOND BARBED 2 STAINLESS ~;~~;~~;~ STEELI I(inches)ROOND BARBED 2 STAINLESS STEEL ROOND 3 GALVALUMEROOND 3 STAINLESS STEEL ROOND 3 STAINLESS STEELRECTANGULAR 1 1/2 X 2 GALVALUME RECTANGULAR 1 1/2 X 2 GALVALUME16. Instellatlon EquipmentScrew gun (optional/required)Installation tool with screw gun (optional/required)Special tool needed (optional/required)OtherREQUIREDDPT I DNALHAMMER DRILL (REQUIRED)SDS SPIKE DRIVER (DPTIONAL)HAMMER DRILL (REQUIRED)17. Average Pullout Reslslance (Ibs.)(FM Tinius Olsen pullout resistance tests,3.00DPSI aged 28 days) 1.100 1,10018. Meets the FM Approvel Requirements as aComponent of Class I Concrete Roof Construction(yes/no) YES YES19. Accapted by the following Codes FM. UL, METRO-DADE COONTYFM, UL20. Warranty Available from Manufacturer (yesino) YES YES21. See Appendix If CheckedNA = not applicable462

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!