11.07.2015 Views

! j I I - National Roofing Contractors Association

! j I I - National Roofing Contractors Association

! j I I - National Roofing Contractors Association

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

w_" 466Roof Fasteners: Lightweight Concrete,Gypsum, or Cementitious Wood Fiber Decks1. Company Name' CARLISLE SYNTEC SYSTEKS THE CELOTEX COR~ATION2. Pnlduct NameHP LIGHTWEIGHT FASTENERANCHORBOND TOGGLE BOLT3. Country 01 Manulactu18 U.S. U.S.4. Deck ~peA. Lightweight concrete X XB Gypsum X XC Cementitious wood fiber X X5. Used with:A. Insulation anachment X XB Built-up membranesXC Single-ply membranesX6. Materlal1)'pe NYLON CARBON STEEL7. Co8led (yesino) NO YESe. Co8llng Type.NA FLUOROCARBON9. Shank ~pe SPIRAL THREAD THREADED10. Point ~pe GIKLET NA11. Method 01 Attechment THREADED, SUBSTRATE C()4PACTIONPREDRILL TOGGLE & \lINGS12. Diameter, t.ngth, Futenlng Range, Penetl8llon - 1 I 2 I 3 I ~ 1 I 2 I 3 I ~Column 1 Column 2 ====~~~;=======~=============~;~=======~=~;~====== ====~~~~~======~============~=;;~======~=~;~======Shank dIameters Shank lengths 0.~3 2 1/2 1 1 1/2 0.215 8 6 3/~ 1 1/~avaIlable available 0.~3 3 1 1/2 1 1/2 0.215 10 8 3/4 1 1/4(Inches) (Inches) 0.43 3 1/2 2 1 1/2 0.215 12 10 3/4 1 1/4Column 3 Column 4 0.43 4 21/2 1 1/2 0.215 14 123/4 1 1/4Fastening range. Minimum required 0.43 4 1/2 3 1 1/2 0.215 16 14 3/4 1 1/4maximum total thickneas deck penetration 0.43 5 3 1/2 1 1/2(inches) (inches) 0.43 5 1/2 4 1 1/20.43 6 41/2 1 1/20.43 61/2 5 1 1/20.43 7 5 1/2 1 1/20.43 71/2 6 1 1/20.43 8 61/2 1 1/2, 0.43 81/2 7 1 1/20.43 9 71/2 1 1/20.43 91/2 8 I 1/20.43 10 81/2 I 1/213. Hesd Shape ROUND, 1/4-IN. RECESS TRUSS14. Heed Dlmenslona (inchea)Thickness 0.12 0.109Diameter 1.0 0.43715. PlateaA Required (yes/no) YES YESB Available from manufacturer (yes/no) YES YES16. ~:::~pe, Dlmen~~:~~n: M8ierlal Column 3==;~:~=~~;=~~==l=======~=======l====~~:~~~~==== ======;~:~=====l====~==~=======l==~~~~=~~~~=====ShapeI Dimension I Material ROUND BARBED 3 GAL VALUKE HEX 2 7/8 GAL VAN I ZED(inches) HEX 2 7/8 PLASTIC17. Inatallatlon EquipmentScrew gun (optional/required)REQUIREDInstaliation tool with screw gun (optional/required)Special tool needed (optional/required)Other IKPACT \/RENCH, ELECTRIC DRILL (OPTIONAL) TOGGLE TOOL, ADHESIVE1B. Ave18ge Pullout Reslatance (Ibs.)A Lightweight concrete decks 350 480/590B. Gypsum decks 350 ~76/600C Cementitious wood fiber decks 350 ~76/60019. Accepted by the lollowlng codes:A. Lightweight concrete decks FK, 6OCA, ICBO, KETRO.-DADE COUNTYB Gypsum decksFK, 6OCA, ICBO, KETRO.-DADE COUNTYC Cementitious wood fiber decksFK, BOCA, ICBO, KETRO. -DADE COUNTY20. Warranty Available from Manulecturer (yes/no) YES YES21, See Appendix II CheekedNA = not applicable

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!