AES 2135BNS <strong>Co</strong>mpatible Safety <strong>Co</strong>ntrollersFeatures• <strong>Co</strong>ntrol Category 3 to EN 954-1• 1 enabling circuit• Enable delay time can be modified• Monitoring of mechanical position switches,safety switches, solenoid interlocks, codedmagnet sensors or E-stops• Can be changed from NO-NC to NC-NCcontact combination• Can be used as emergency-stop controllerfor Category 0 to EN 60204-1• Monitoring for short-circuit betweenconnections with NO-NC contactcombination• ISD Integral System Diagnostics• <strong>Co</strong>nnection of input expansion modulespossible• 2 semiconductor auxiliary outputs (nonsafety)Dimensions45 x 100 x 121 mmISDThe following faults are recognized by the safetycontroller and indicated by means of ISD• Failure of door contacts to open or close• Short-circuits on or between the switch connections• Interruption of the switch connections• Failure of the unit’s internal safety relay to pull-in ordrop-out• Faults on the input circuits or on the relay controlof the guard door monitorModelDesignationAES 2135 24-230V AC/DCFunctionTableAdditional semiconductoroutput YFunction of output YSwitching <strong>Co</strong>nditionAES 2135 Y1 Enable Enable circuit closedY2 No enable Enable circuit openApprovals BG UL CSA166