11.07.2015 Views

New! - Norman Equipment Co.

New! - Norman Equipment Co.

New! - Norman Equipment Co.

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Safety light barriersSLB 200-C• To IEC 61496• <strong>Co</strong>ntrol Category 2 to EN 954-1, BWS-T• Up to two pairs of light barrier devicescan be connected• 1 enabling path• 1 signalling output• Operating voltage 24 VDC• Test input• LED display of switching conditions• Response time ≤ 30 ms• Start/Restart interlock can beswitched active or inactive• <strong>Co</strong>ntactor monitoring can beswitched active or inactive• Additional cyclic testing• <strong>Co</strong>-ordinated for use withSLB 200 R/E safety light barriersTechnical dataStandards: IEC/EN 61496-1/-2, EN 954-1<strong>Co</strong>ntrol category: 2Start-up test:yesStart conditions:Test button, start-reset button, on/off codingFeedback circuit:yesEnclosure:polycarbonateMounting: snaps onto standard DIN rail to EN 50022<strong>Co</strong>nnection:screw terminalsCable section:max. 4 mm 2 (incl. conductor ferrules)Protection class: IP 20 to EN 60529Ue: 24 VDC ± 20%Ie:180 mAPower consumption: –Inputs:test input: command device: NC contactrelease start/restart interlock (start/reset): enable via commanddevice (NO contact), contactor monitoring (NC contacts)Monitored inputsmax. 2 pairs of light barriersInput resistance: –Max. cable length: –Test and feedback:potential-free contactOutputs:1 enabling pathEnabling contacts:1 enabling pathUtilisation category:AC-15, DC-13Ie/Ue:2 A / 250 VAC, 2 A / 24 VDC<strong>Co</strong>ntact load capacity: max. 250 VAC, max. 2 A (cos ϕ = 1)Switching voltage:max. 250 VACLoad current:8 AMax. fuse rating:4 A gG D-fuseSignalling output:1 transistor outputSwitch-on conditions:test duration: ≤ 150 ms (without relay control)≤ 450 ms (with relay control)Switch-off time:response time (complete sy.): ≤ 30 msIndications:red LED for light barrier interruptedgreen LED for light barrier freesoiling: flashing red/greenFunction display:4 LEDsEMC rating:conforming to EMC DirectiveMax. switching frequency:10 HzOvervoltage category: II to DIN VDE 0110Degree of pollution: 3 to DIN VDE 0110Resistance to vibration:10 ... 55 Hz / amplitude 0.35 mmResistance to shock:10 g / 16 msAmbient temperature: 0 °C … + 50 ºCStorage and transport temperature: – 20 °C … + 80 ºCDimensions:45 x 84 x 118 mmNote:Inductive loads (e.g. contactors, relays, etc.) areto be suppressed by means of a suitable circuit.ApprovalsOrdering detailsSLB 200-C04-1R304

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!