AZS 2305TypicalApplications2TypicalWiringDiagramA1S13S14S21AZM 16013 14 21 22 1 2 3 4 5 6+24 VDC0 0V+24 VDCS22H1N0VL1X1 X2 Y1 Y2 13 23 33 SA1 Y1 Y2 13 23 33H2L1Emax.100mAmax.100mAK1K1K2K20VA2X3 X4 X5 X6 X7 X814 24 34 A2 S13 S14 S21 S22 14 24 340VAES 3335/3336 AZS 2305NK3SK1K43MApplicationNotes• The arrangement in the wiringdiagram fulfills <strong>Co</strong>ntrol Category 1to EN 954-1.• <strong>Co</strong>ntrol Category 3 can beachieved. Exclusion of faults dueto “Breakage or release of theactuator, fault in the solenoidinterlock” is to be substantiatedand documented.• Monitoring of a sliding, hinged orremovable guard device using anAZM range solenoid interlock (A).• The solenoid interlock releases theguard device only when the settime has elapsed. The time beginsto run when the power contactorshave dropped out.• The AES range guard door controllerchecks the position of theguard device.• The coil of the solenoid interlock isenergized by operation of the pushbuttonE• After release has taken place, theguard device must be opened if H1is not connected.• The wiring diagram is with theguard device closed and showsthe de-energized condition.75