11.07.2015 Views

New! - Norman Equipment Co.

New! - Norman Equipment Co.

New! - Norman Equipment Co.

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

OSSD FALOSSD FAILCSafety light curtains and safety light gridsSLC 210453585 24 40==BA10• Safety light curtain• <strong>Co</strong>ntrol category Type 2to IEC/EN 61496-1, -2• Resolution 20, 30, 40, 50 and 90 mm• Protection field heightfrom 160 mm to 1810 mm• Range from 0 ... 16 m• Self-test every 0.5 s• semiconductor outputs• Optical synchronisation• Status display• Protection class IP 65Legend:A: Total length (B + 91 mm)B: Protection field heightC: 85 mm (SLC)ApprovalsOrdering detailsSLC 210-E/R➀-➁-12-➂No. Replace Description➀ xxxx Height of protection fieldAvailable lengths:0160 mm*** 0310 mm0460 mm 0610 mm0760 mm 0910 mm1060 mm 1210 mm1360 mm 1510 mm1660 mm 1810 mm➁ 20, 30 Resolution 20, 30 mm40, 50 Resolution 40, 50 mm90 Resolution 90 mm➂Range 6 mHRange 1 ...16 mHigh RangeSLG 2103545 = =2440• Safety light grid• 2-, 3- or 4-beam light grid• Protection field heights 510 mm,810 mm or 910 mmApprovalsOrdering detailsSLG 210-E/R➀-12-➁BA10No. Replace Description➀Distance betweenoutermost beams:0500-02 500 mm, 2-beam0800-03 800 mm, 3-beam0900-04 900 mm, 4-beam➁Range 0 ... 6 mHRange 1 ...16 mHigh RangeMounting brackets and T-slots are included inthe delivery.*** only for resolution 20, 30 mmTechnical dataStandards: IEC/EN 61496-1/-2<strong>Co</strong>ntrol Category toIEC/EN 61496-1, -2 Type 2Enclosure:AluminiumEnclosure dimensions:35 x 45 mm<strong>Co</strong>nnection: connector plug M 12,5-poleMax. cable length:100 mProtection class: IP 65 to EN 60529Response time:5,5 – 28 ms(depends onlength and resolution)Detection sensitivity (Resolution): 20, 30, 40,50 and 90 mmProtection field height:(Resolution: 20, 30 mm): 160 ... 1810 mm(Resolution: 40, 50, 90 mm): 310 ... 1810 mm(2-, 3-, 4-beam): 510, 810, 910 mmProtection fieldwidth, range:0 ... 6 m (Standard),1 ... 16 m (High range)Start/restart interlock: *<strong>Co</strong>ntactor control: *Light emission wavelength: 950 nm (infrared),codedUe: 24 VDC ± 20%Safety outputs:2 x PNP, 500 mALeakage current: **Safety outputs:< 0,3 mAPower consumption: Emitter 2 W,Receiver 3 WData interface: –Status anddiagnostics displayLED indicationAmbient temperature: 0 °C … + 55 ºCStorage andtransport temperature: – 20 °C … + 70 ºC* only in combination with safetymonitoring module** In case of failure (interruption of the0 V supply) the maximum leakagecurrent is 0.3 mA.Ordering detailsAccessories:<strong>Co</strong>nnector plug M 12 x 1for Emitter/ ReceiverKD M12-5-5 mKD M12-5-15 mfor Emitter/ Receiver(pre-wiring possible, however without cable)R = angled connector KD M12-5-RS = straight connector KD M12-5-SFurther accessories can befound on pages 292-294.275

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!