SERIES MZM 100 WIRING EXAMPLESafety Sensors in large systemsThe sensors have separate inputand output cables. The output of onesensor can be directly wired into theinput of the next sensor. The sensorchain can be built up over a length oftwo hundred meters.The supply voltage is wired in bothsafety inputs of the last solenoidinterlock of the chain (starting fromthe control relay). The safety outputsof the first interlock are wired to thecontrol relay.SERIES CONNECTION OF MZM 100Safety outputs -> <strong>Co</strong>ntrol relayWIRING OF THE INTEGRATED CONNECTOR MZM 1006Solenoid interlock with diagnostic outputPin configurationA1 Supply Voltage . . . . . . . . . . . . . . . . . . . . . . . . .Pin 1A2 Ground . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Pin 3X1 safety input 1 . . . . . . . . . . . . . . . . . . . . . . . . . .Pin 2X2 safety input 2 . . . . . . . . . . . . . . . . . . . . . . . . . .Pin 6Y1 safety output 1 . . . . . . . . . . . . . . . . . . . . . . . . .Pin 4Y2 safety output 2 . . . . . . . . . . . . . . . . . . . . . . . . .Pin 7OUT diagnostic output . . . . . . . . . . . . . . . . . . . . . . .Pin 5IN magnet control . . . . . . . . . . . . . . . . . . . . . . . . .Pin 8193