12.07.2015 Views

SDISC Assembler Call - NetEx

SDISC Assembler Call - NetEx

SDISC Assembler Call - NetEx

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

CONF074E Invalid trunk (0,1) defined on 715 link ‘trunk’, NETADDR= ‘ad’Explanation: 715 links may only have trunks 2 and/or 3 attached.System Action: Ignore statement, free up memory allocated and get next card.CONF080E BUS not previously defined: ‘busname’Explanation: A BUS = parameter has been encountered, but the name does not match any previouslydefined HB statements.System Action: Ignore statement, free up memory allocated and get next card.CONF081E BUS not meaningful with “A” type adapter: ‘busname’Explanation: “A” type adapters may not be attached to a BUS.System Action: Ignore statement, free up memory allocated and get next card.CONF082E BUS missing in ADAPTER/LINK statement: ‘netaddr’Explanation: “B” type adapters must be attached to a BUS.System Action: Ignore statement, free up memory allocated and get next card.CONF083E Invalid SEGSIZE value: ‘value’Explanation: SEGSIZE as specified on a PORT statement is > 65535.System Action: Ignore statement, free up memory allocated and get next card.CONF087F Line length exceeds 64 charactersExplanation: The line that follows is longer than 64 characters.System Action: Edit the line to 64 characters.Second Pass Configuration MessagesA formal description of the pass two configuration errors follow. The actual value of the identifier will replacean identifier enclosed in single quotes (for example: ‘HOSTname’). All errors except CONF044,CONF046, CONF048, and CONF054, and CONF057 set the NCT validation flag (ValidNCT) to FALSE.This flag is always checked before accessing the NCT.CONF03SE Multiple adapters must have same ‘operand’ valueExplanation: A multi-port adapter was encountered with duplicate NETADDRs but the one of theother operands don't match in both statements.System Action: Display error message, set ValidNCT flag to FALSE and continue processing.CONF036E ADAPT operand: ‘operand’ must equal adapter label: ‘label’Explanation: A multi-port adapter/link was encountered with duplicate NETADDRs but theADAPT operand doesn’t match the previous label.System Action: Display error message, set ValidNCT flag to FALSE and continue processing.CONF037E Multi-port adapters must not have same PORTExplanation: A multi-port adapters was encountered with duplicate NETADDRs but the PORT operandsare not different.System Action: Display error message, set ValidNCT flag to FALSE and continue processing.CONF03SE Duplicate labels in configuration: ‘label’Explanation: An entity was encountered with the same label as a previously defined entity.System Action: Display error message, set ValidNCT flag to FALSE and continue processing.CONF039E No adapter specified for HOST: ‘HOSTname’Explanation: No adapter was specified for this host. At least one is required for each host.System Action: Display error message, set ValidNCT flag to FALSE and continue processing.CONF040E No SMGR specified for HOST: ‘HOSTname’Page 116 Appendix B. ConfMang Messages MAN-REF-H307IP-04

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!