12.07.2015 Views

SDISC Assembler Call - NetEx

SDISC Assembler Call - NetEx

SDISC Assembler Call - NetEx

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Explanation: No SMGR was specified for this host. At least one is required for each host.System Action: Display error message, set ValidNCT flag to FALSE and continue processing.CONF043E HOST: ‘HOSTname’ has GROUP name equal to real HOST name: ‘name’Explanation: A GROUP name was encountered that has the same name as a real HOST name.System Action: Display error message, set ValidNCT flag to FALSE and continue processing.CONF044I No PORT found with label: ‘label’Explanation: A DEST label was encountered and the PORT referred to by the label is not defined.System Action: Display error message and continue processing. This is only a warning message.CONF045E Invalid PORT linkage: ‘link model’,‘link model’Explanation: A PORT was encountered that is not a valid linkage to the PORT described in theDEST label. PORTs must connect LINKs of the same type except for x4xx links.System Action: Display error message, set ValidNCT flag to FALSE and continue processing.CONF046I No path from HOST ‘HOSTname’ to HOST ‘HOSTname’Explanation: There is no path connecting HOST A with HOST B. Communication between thesehosts cannot take place.System Action: Display error message and continue processing. This is only a warning message.CONF047E Missing a multi-port ADAPTER with the label: ‘label’Explanation: There is no adapter with the specified label; there must be for all x4xx adapter/links.System Action: Display error message, set ValidNCT flag to FALSE and continue processing.CONF048I The erroneous values are ‘value’ and ‘value’Explanation: An error was encountered in which these two values are incorrect.System Action: Display error message, set ValidNCT flag to FALSE and continue processing.CONF049E Multi-port adapters can’t have 2 labels ‘label’, ‘label’Explanation: An error was encountered in which these two values are incorrect.System Action: Display error message, set ValidNCT flag to FALSE and continue processing.CONF050E Multi-task adapters require unique SMGDREFsExplanation: On a multi-process host, two adapters were encountered with the same NETADDRand the same SMGDREF. The SMGDREF values must be different. See ADAPTER statement sectionfor details on multi-process hosts.System Action: Display error message, set ValidNCT flag to FALSE and continue processing.CONF051E Multi-task adapters require same PORT numbersExplanation: On a multi-process host, two adapters were encountered with the same NETADDRand different PORT numbers. The PORT values must be the same. See ADAPTER statement sectionfor details on multi-process hosts.System Action: Display error message, set ValidNCT flag to FALSE and continue processing.CONF053E Duplicate network address: ‘address’ in LOCALNET: ‘label’Explanation: An adapter other than model PB40x/NB40x was encountered which specifies the sameNETADDR as a previously defined adapter on the same network.System Action: Display error message, set ValidNCT flag to FALSE and continue processing.CONF054I The above NETADDR = an implicitly defined A722Explanation: The NETADDR specified in the above error message is the same as the A722 unit ofan S720 SLS.System Action: Display error message, continue processing. This is only a warning message to explainthe previous error further.CONF055E HOST: ‘name’ and HOST: ‘name’ in GROUP: ‘name’ need same protocolsMAN-REF-H307IP-04 Appendix B. ConfMang Messages Page 117

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!