12.07.2015 Views

Practice of Kinetics (Comprehensive Chemical Kinetics, Volume 1)

Practice of Kinetics (Comprehensive Chemical Kinetics, Volume 1)

Practice of Kinetics (Comprehensive Chemical Kinetics, Volume 1)

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

2 THE SOLID-GAS INTERFACE 243limit for omegatron operation, the collector current only decreases by 0.5 % withthe emission control in operation. Without the emission regulator, the sameincrease in oxygen pressure causes the collector current to decrease to 10% <strong>of</strong> itsoriginal value, making quantitative measurements impossible.(c) TopatronThe'theory <strong>of</strong> this type <strong>of</strong> spectrometer was discussed by Bennett266 and byRedhead and Cro~ell*~~. It is a resonance spectrometer operating on the principle<strong>of</strong> a linear accelerator. The constrdction and operation <strong>of</strong> the device has beendescribed by Vkradi et ul.268~269t and by Ehlbeck et al.270s271.It has the advantage <strong>of</strong> measuring total pressure as well as partial pressure andrequiring no magnet. A schematic diagram <strong>of</strong> the device is shown in Fig. 35. Thetube consists <strong>of</strong> two compartments. One contains an ion source consisting <strong>of</strong> athoria-coated tungsten filament and a box shaped anode (A). Ions are producedin the box and are then attracted by the first negatively charged grid (Gl). Aproportion <strong>of</strong> the ions are collected at this grid and the measured ion current isproportional to the total pressure. Ions not trapped at G1 travel through theanalysing grid system (G2-G12) which has an rf voltage between each alternategrid. If the ions have the correct velocity V to clear a grid distance S during a halfperiod <strong>of</strong> the rf cycle, they gain energy from the rf field and are able to reach thecollector S. From the relationshipwhere f is the radio frequency in Mc. sec-' and V, is the ion accelerating voltage,eJM can be found.After bake-out at temperatures <strong>of</strong> up to 450" C, the tube will operate over thepressure range 10-3-10-8 torr. Mass numbers up to 100 can be resolved, or upto 250 at the expense <strong>of</strong> sensitivity.(d) FarvitronThe farvitron, which is also a resonance spectrometer, was developed by Reichand B a ~ h l efrom ~ work ~ ~ ~ by ~ Tretner274. ~ ~ A schematic diagram <strong>of</strong> this instrumentis shown in Fig. 36:. Electrons emitted from the filament (K) are acceleratedby the grid W and ionize the gas inside electrode A. The ions formed aret A commercial instrument is marketed by Leybold in Europe and by the Raytheon Co. in theU.S.A.The instrument developed by Reich and Bgchler is available commercially from E. LeyboldNachfolger, Germany.References pp. 270-278

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!