5.3.8 Outriggers5.3.8.1 Where outriggers are used, the outriggers should be :(a)(b)<strong>of</strong> adequate length <strong>and</strong> strength <strong>and</strong> properly installed <strong>and</strong> supported;firmly anchored at the inner ends; <strong>and</strong>(c) securely fastened to any ballast or counterweights (regulation 5(2)<strong>of</strong> the SWPR).5.3.8.2 Outrigger should be properly constructed. It should not contain weldedjoint when it is in tension unless the joint is supplemented. Any weldedsteel joints should con<strong>for</strong>m in all respects to BS 5135: 1984 or equivalent.5.3.8.3 Special attention should be given to ensure that the strength <strong>of</strong> the buildingor structure is adequate at places where the outrigger bears on the buildingor structure.5.3.8.4 Where ro<strong>of</strong> hooks <strong>and</strong> parapet wall clamps are used to serve the purpose<strong>of</strong> outriggers (see Fig. 5) <strong>of</strong> a temporary suspended working plat<strong>for</strong>m,the following requirements should be followed:(a)there should be sufficient tie-backs anchored onto the ro<strong>of</strong> beamsor internal columns <strong>of</strong> the building;(b) every tie-back should be <strong>of</strong> steel wire rope having a diameter notless than that <strong>of</strong> the suspension rope;(c)(d)(e)(f)(g)a turn-buckle or other similar device should be incorporated in everytie-back;every tie-back should at all times be kept taut;the ro<strong>of</strong> hooks, parapet wall clamps <strong>and</strong> anchor points <strong>of</strong> tie-backshould not be used on non-rein<strong>for</strong>ced structures such as masonry<strong>and</strong> brick wall;any packing used should be securely clamped; <strong>and</strong>suitable stiffener should be used to prevent the open-up <strong>of</strong> theoutrigger leg.5.3.8.5 A rope guard or other means should be fitted at the outer end <strong>of</strong> theoutrigger to prevent the suspension rope <strong>and</strong> safety rope from slipping<strong>of</strong>f the outrigger.24

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!