Code of Practice for Safe Use and Operation of Suspended Working ...

Code of Practice for Safe Use and Operation of Suspended Working ...

Code of Practice for Safe Use and Operation of Suspended Working ...

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

5.14.7 All electrical equipment <strong>and</strong> wiring should be protected against overloads,short circuits <strong>and</strong> earth faults. Enclosure <strong>for</strong> electrical equipment whichare exposed to open air should be protected from ingress <strong>of</strong> water orsolid <strong>for</strong>eign objects by having an IP (Ingress Protection) rating <strong>of</strong> notless than 54 according to BS EN 60529:1992. All terminals should beprotected from corrosion.5.14.8 The power supply <strong>for</strong> the suspended working plat<strong>for</strong>m should be providedwith appropriate overload short circuit <strong>and</strong> earth-fault electrical protection.Power supply cables passing over parapets, edges <strong>of</strong> ro<strong>of</strong>s or over thecorners <strong>of</strong> beams or slabs should be protected from abrasion or othermechanical damage.5.14.9 Any plug <strong>and</strong> socket should be so placed that they would not be damagedby the intended movement <strong>of</strong> the working plat<strong>for</strong>m or by the accidentalswinging <strong>of</strong> the working plat<strong>for</strong>m against the building.5.14.10 All control units <strong>and</strong> pendant controls should be so marked <strong>and</strong> identifiedthat there is no confusion between the various controls. Their purpose<strong>and</strong> the direction <strong>of</strong> travel resulting from their operation should be clearlyidentified.5.14.11 Pendant controls should be so placed or fixed that they cannot bedamaged by the intended movement <strong>of</strong> the working plat<strong>for</strong>m or by theaccidental swinging <strong>of</strong> the working plat<strong>for</strong>m against the building. Thecontrol button or levers should be robust <strong>and</strong> require continuous lightpressure to maintain powered movements, <strong>and</strong> the control units shouldbe so designed as to prevent them from being operated accidentally, e.g.by the provision <strong>of</strong> shrouds.5.14.12 If 3-phase induction motors are employed as power drives <strong>of</strong> thesuspended working plat<strong>for</strong>m, protection devices should be provided toprotect against single phasing <strong>and</strong> wrong phase sequence.5.14.13 Cable reels or other suitable device should be used <strong>for</strong> the proper h<strong>and</strong>ling<strong>of</strong> the cables connected from the fixed building to the working plat<strong>for</strong>m. Itis to minimize the risk <strong>of</strong> physical damage to the cables due to stress <strong>and</strong>strain. It also helps to eliminate the risk <strong>of</strong> trip <strong>and</strong> trap to the operators.37

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!