12.07.2015 Views

Plant 44 Audit Reports - Wright-Patterson Air Force Base

Plant 44 Audit Reports - Wright-Patterson Air Force Base

Plant 44 Audit Reports - Wright-Patterson Air Force Base

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

FOR OFFICIAL USE ONLYDistribution authorized to DoD components and their contractors only; administrative/operationaluse; August 8, 2005. Other requests for this document shall be referred to the Chief, AcquisitionEnvironmental Safety & Health Division, Engineering Directorate, ASC/ENV, <strong>Wright</strong> <strong>Patterson</strong> <strong>Air</strong><strong>Force</strong> <strong>Base</strong>, OH 45433CC. Building 864 A walk-through of the building was accomplished. The followingfacility housekeeping and maintenance discrepancies were noted:i. A temperature and humidity sensor mounted on the wall in the test bay is nolonger used and needs to be removed.ii. The exterior exit door in the chemical lab was blocked on the outside by aporta-john.iii. The lab is constructed as a class I, division I room, however the computersare located on the floor. If this is a class I, division I area then the computers need to beinstalled in another location above the floor.IV. The wall-roofjoint on the fuel pump house is badly cracked and needs to berepaired.dd. Building 865 A walk-through of the building was accomplished. Building 865is a small building (280 SF) built in 1975 and utilized for TOW testing. In 2002 thisbuilding was found to have numerous discrepancies caused by a lack of normalmaintenance. The necessary maintenance work has been completed and this facility isgreatly improved.i. Temporary test equipment located outdoors in the test range area was poweredwith multiple extension cords and power strips. This is an inadequate method to provideelectrical power. This setup needs to be replaced with a hardwired, weather proofelectrical outlet.ii. The occupant pointed out that the FACO public address system does not reachbuilding 865 or the associated test range.ee. Building 866 A walk-through ofthe building was accomplished. Damagedsiding along the ramp needs to be repaired.ff. Building 867 A walk-through ofthe building was accomplished. Nohousekeeping or maintenance discrepancies were noted.gg. Building 868 A walk-through ofthe building was accomplished. The followingfacility housekeeping and maintenance discrepancies were noted:i. The evaporative cooler R85E027 is badly corroded around the base of theunit. If necessary, repair or replacement of this unit should be considered for futureconsideration as a "other than normal maintenance" CTR project.ii. Asphalt paving around the building needs to be maintained with crack repairsand seal coating.iii. The eyewash unit outside the loading dock has a broken foot pedal.iv. Housekeeping attention is required in the electrical equipment room (868-2).Debris, old heat detectors, conduit and other junk needs to be removed.v. A new modular office unit has been requested for installation at building 868.An explosive site plan has been submitted for approval; the approval has not yet beengranted. It was observed that trenching for the utility services has already been startedwithout the necessary approvalS.Attachment 1

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!