12.07.2015 Views

Plant 44 Audit Reports - Wright-Patterson Air Force Base

Plant 44 Audit Reports - Wright-Patterson Air Force Base

Plant 44 Audit Reports - Wright-Patterson Air Force Base

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

FOR OFFICIAL USE ONLYDistribution authorized to DoD components and their contractors only; administrative/operational use; August19,2005. Other requests for this document shall be referred to the Chief, Acquisition Environmental Safety &Health Division, Engineering Directorate, ASCIENV, <strong>Wright</strong> <strong>Patterson</strong> <strong>Air</strong> <strong>Force</strong> <strong>Base</strong>, OH 45433Item # 005 Are sufficient number and type of vehicles available to meet mission requirements?Raytheon has one 1250 gpm engine and one 750 gpm engine. They also have one rescue vehicle. A fuelloading analysis needs to be made of Raytheon's most hazardous non sprinkled facility to determine fire flowrequirements. This will determine if the current pumpers can meet the fire flow demand. (action item)Ref: AFI 32·2001, 3.1.2.1Item # 006 Are sufficient personnel on duty to properly staff vehicles?No. There are 5-8 fire fighters on duty. Required per DoD! 6055 is 4 fire fighters per truck per shift andthey'll need two trucks for first response. A rescue vehicle also has to be staffed with three fire fighters.Including the incident commander, this translate to 12 fire fighters per shift. (action item)Ref: AFI 32-2001, 3.1.2Item # 007 How do the Fire Chief and <strong>Base</strong> Civil Engineer inform the installation commander of fire departmentcapabilities?Within Raytheon's management structure, the telephone is the most common means of communicating firedepartment capabilities.Ref: AFI 32-2001, 3.1.2Item # 008 Has the Fire Chief established standard operating procedures on incident response priorities for approval bythe installation commander?No - Raytheon's management structure does not require a SOP (action item).Ref: AFI 32-2001, 3.12.3Item # 009 Do firefighters perform additional duties outside the fire department compromising mission support and <strong>Air</strong><strong>Force</strong> acceptable levels of risk for safe fire fighting as determined by the Fire Chief?No - The fire fighters do not perform additional duties outside the fire department mission.Ref: AFI 32-2001, 3.16 & Atch 3Item # 010 Are emergency responses reported lAW the automated Fire Incident Reporting System?No - Raytheon does not use FIRS or any other type of automated reporting system. (action item to establishprocedures)Ref: AFI 32-2001, 3.1.7 & Atch 4 and 6ATeH 1

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!