12.07.2015 Views

Synchrophasor Initiative in India - erldc

Synchrophasor Initiative in India - erldc

Synchrophasor Initiative in India - erldc

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

SYNCHROPHASORS - INITIATIVE IN INDIA JUNE 2012the control centre which hitherto was possible only <strong>in</strong> offl<strong>in</strong>e mode <strong>in</strong> the form of substationDisturbance Records or through offl<strong>in</strong>e dynamic simulations performed on network models.The Phasor Measurement Unit (PMU) is the basic build<strong>in</strong>g block of Wide Area MeasurementSystem (WAMS). The PMU measures the system state viz. voltage and angle of a particularlocation at a rate of multiple samples per second (say 25 samples per second). This data is timestamped through a common reference and transmitted to the Phasor Data Concentrator (PDC)<strong>in</strong>stalled at a nodal po<strong>in</strong>t, through high speed wideband communication medium (such asOptical Fibre). The PDC aligns the time synchronized data and presents it to the User/Historian.The Historian archives the data for retrieval and post-dispatch analysis of any grid.World over the synchrophasor technology is <strong>in</strong>creas<strong>in</strong>gly be<strong>in</strong>g used for supplement<strong>in</strong>g theconventional SCADA / EMS for provid<strong>in</strong>g a wide area visibility and enhanc<strong>in</strong>g situationalawareness at the control centre. In <strong>India</strong>, pilot/ demo projects have been taken up or envisaged<strong>in</strong> all the five regions. This report enumerates the features available <strong>in</strong> the synchrophasorpilot/demo projects taken up <strong>in</strong> <strong>India</strong> s<strong>in</strong>ce May 2010. It provides a compilation of case studiesdescrib<strong>in</strong>g various real-time and offl<strong>in</strong>e application of the synchrophasors data. The reporthighlights the major challenges encountered <strong>in</strong> the tenure of the past two years. The reportconcludes with the proposed suggestions, future scope and probable roadmap for furtherexploitation of synchrophasors technology <strong>in</strong> <strong>India</strong>.Overview of the synchrophasor <strong>in</strong>itiative <strong>in</strong> <strong>India</strong>In <strong>India</strong>, fourteen (14) Phasor Measurement Units (PMUs) have been commissioned as on 31 stMay 2012. In the Northern Region, the PMUs have been placed at n<strong>in</strong>e 400 kV substations viz.V<strong>in</strong>dhyachal (HVDC back-to-back station), Kanpur (with SVC), Dadri (HVDC <strong>in</strong>verter term<strong>in</strong>al),Moga, Kishenpur, Agra, Bassi, Hisar and Karcham Wangtoo. In Western Region PMUs havebeen placed at two 400 kV substations viz. Raipur and Bhadravati. In Southern Region, theyhave been placed at three 400 kV substations viz. Salem, Hyderabad and Bengaluru. The threePhasor Data Concentrators (PDC) have been <strong>in</strong>stalled at the respective Regional LoadDespatch Centres (RLDCs) located <strong>in</strong> New Delhi, Mumbai and Bengaluru. Placement ofPMUs/PDCs at few more locations <strong>in</strong> <strong>India</strong> has been envisaged under the pilot projects takenup by the RLDCs. The WAMS <strong>in</strong> Western and Southern Region are demonstration projects,while <strong>in</strong> the Northern Region the expenditure under the pilot project was approved by theHonourable Central Electricity Regulatory Commission (CERC) and funded from theUnscheduled Interchange Pool Account.Application of synchrophasor data available through the pilot projectThough the synchrophasors data is presently available only from a few locations <strong>in</strong> the <strong>India</strong>ngrid, yet it has dramatically raised visualization and the level of understand<strong>in</strong>g of the powersystem at the control centres with<strong>in</strong> few months of its commission<strong>in</strong>g. It has enhancedsituational awareness <strong>in</strong> real-time. In the offl<strong>in</strong>e mode the synchrophasors data is be<strong>in</strong>g utilizedPOSOCO Page 8 of 143

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!