12.07.2015 Views

Grundfos Alldos DDI-209 User Manual - Industry Surplus Australia

Grundfos Alldos DDI-209 User Manual - Industry Surplus Australia

Grundfos Alldos DDI-209 User Manual - Industry Surplus Australia

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

6.1.4 Remote on/off / contact input / current inputSocket 4For the remote on/off input and contact input orcurrent input.If the remote on/off and contact inputs are to be usedat the same time, wire 1 is assigned twice.CautionFor the connection of one cable, use aplug adapter with simple cable entry,for the connection of two cables, use aplug adapter with double cable entry,otherwise the protection will be lost!Socket 4 Cable Used forPin Assignment Wire colour6.1.5 Empty signal only / pre-empty and empty signalSocket 5For the empty signal only or pre-empty and emptysignal input.The suction lines with empty signal or pre-empty andempty signal are pre-assembled with a plug forsocket 5.Remote on/offinputContact input+/– currentinput1 GND Brown x x –2 Current input White +3 Remote on/off input Blue x4 Contact input Black xSocket 5Used forPin Assignment Empty signal Pre-empty signal1 Empty signal x2 GND x x3 Pre-empty signal x27