Pressure exceededIf, after three successive strokes, the cut-offpressure is exceeded, this is recognised as an error:• The pump is stopped.• The error signal relay switches on.• The LED alternately flashes red and green.• The last pressure value to be measured isdisplayed.• "RUN", "ERROR" and "bar" flash in the display.RUN*ERROR*<strong>Manual</strong>8.99bar*TM03 6578 4506Pump restart attempts:• First the pump makes four attempts to restart,each separated by a 2-second pause, if thechamber pressure has fallen below the cut-offpressure (p act < p set ).• If, after three successive strokes, the cut-offpressure is exceeded, the pump is stopped again.• After four attempts, the pump waits 10 minutesbefore attempting to automatically restart again.• The pump continuously attempts to restart if thechamber pressure decreases in this way.Fig. 60 Display: "Pressure exceeded"Pressure exceededPump runningPump waiting….2 sec. 10 min. 10 min.TM03 6579 4506Fig. 61 Pump restart attemptsError correction• Press the "Start/Stop" button to stop the pumpand prevent it from restarting.• Check the discharge valve and the installation onthe discharge side and correct any errors,if necessary.For maintenance work, see section10. Maintenance.• Check and correct the pressure setting,if necessary.Once the error has been corrected,• press the "Start/Stop" button to restart the pump.– The pump returns to the state it was in beforethe error occurred.Displaying the pressure that has been measuredThe pressure that has been measured during thepump operation can be displayed at any time.• Press the "Menu/Info" button twice.(If only pressed once, the dosed quantity isdisplayed.)– The pressure is displayed for approximately10 seconds.9.10.5 Error message – broken cable or faultysensorIf the dosing controller and/or the pressure controlfunction are/is switched on, the missing signal isrecognised and emitted as an error.A faulty pressure sensor (broken cable) is displayedas follows:• The error signal relay switches on.• The pump is not stopped!• The LED flashes red.• "ERROR" flashes in the display.RUNERROR*<strong>Manual</strong>2.42l/hFig. 62 Display: "Broken cable"Correct error• Press the "Start/Stop" button twice to confirm theerror and to stop the pump.• Repair the cable break.TM03 6580 450656

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!