CautionAfter initial start-up and after each timethe diaphragm is changed, tighten thedosing head screws.After approximately 6-10 operatinghours or two days, cross-tighten thedosing head screws using a torquewrench.Maximum torque:<strong>DDI</strong> 0.4 - <strong>DDI</strong> 5.5: 2.1 Nm.<strong>DDI</strong> 13.8 - <strong>DDI</strong> 20: 2.5 Nm.3q2q1q4q5qQ2VTM03 6269 4506Fig. 72 Replacing diaphragm without Plus 3system0242Q6810ml1q2qD3eTM03 6270 4506Fig. 73 Replacing diaphragm with Plus 3 system66