12.07.2015 Views

Grundfos Alldos DDI-209 User Manual - Industry Surplus Australia

Grundfos Alldos DDI-209 User Manual - Industry Surplus Australia

Grundfos Alldos DDI-209 User Manual - Industry Surplus Australia

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Once the error has been corrected,• press the "Start/Stop" button to restart the pump.– The pump returns to the state it was in beforethe error occurred.NoteIf the cable is broken, the dosingcontroller and pressure control/pressure display functions are notactive. When the "Menu/Info" button ispressed twice to display the chamberpressure, only "— — —" is displayed.9.10.6 Changing the number of permissible error strokesTo change the number of permissible error strokesduring the start-up operation and during normaldosing operation.NoteIf the sensor fault cannot be correctedimmediately and if the pump is tocontinue to run without a sensor,switch off the dosing controller(flow:OFF) and pressure controlfunction (P:OFF).MenuInfoService levelPermissible error strokesduring start-up operationNumber of error strokesuntil the error message istriggeredSt:60ERRORStopStartFE: 7ERRORUpDownUpDownUse the "Up" and "Down" buttons to set thenumber of permissible error strokes duringthe start-up operation in the range between1 and 99.Use the "Up" and "Down" buttons to set thenumber of error strokes until the errormessage is triggered during normal dosingoperation in the range between 3 and 99.StopStartTM03 6575 4506Fig. 63 Permissible error strokes1. Open the service level.2. Repeatedly press the "Menu/Info" button tonavigate in the service level until you reach menuitem "St:60" (error stroke during start-upoperation).– The display shows "St" and the number ofcurrently defined error strokes that arepermissible during the start-up operation.3. Use the "Up" and "Down" buttons to set thenumber of permissible error strokes during thestart-up operation in the range between 1 and 99.4. Press the "Start/Stop" button.– Confirm the setting and go to menu item"FE: 7".– The display shows "FE" and the number ofcurrently defined error strokes that arepermissible during normal dosing operation.5. Use the "Up" and "Down" buttons to set thenumber of error strokes until the error message istriggered during normal dosing operation in therange between 3 and 99.6. Press the "Start/Stop" button– to confirm the new settings– to exit the service level– to open the first function level.9.10.7 Calibrating the sensor after the sensor hasbeen replacedOnce a sensor has been replaced, the new sensormust be calibrated to the ambient pressure.Prepare the pump for the calibration:1. Before screwing in the sensor, check that nodosing liquid is left in the place where thepressure sensor will be screwed in!2. Screw in the new sensor with the correctly fittingO-ring.3. Screw the sensor plug into socket 2.4. Unscrew the suction valve.57

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!