494 Plug-In Assembly ConfigurationCHANNEL 7RELAY KtlI I0CP= CONTP.CT PROTECTIONSEE TEXTCHANNEL 9SEADBAiYCHANNEL 0+SpecificationsFigure 135. Option 115 - Typical ApplicationsSpecifications for the high voltage actuator assembly follow. Specifications are performancestandards, or limits, against which the assembly may be tested.OPTION 1158 CHANNEL HIGH VOLTAGE ACTUATOR ASSEMBLYMaximum Contact Ratings:Voltage AC 252 VRMS DC 48 VDCCurrent AC 2 amps RMS DC 2 ADCPower AC 500 VA per chan. DC 60 VA per chanPeak Surge Current: 10 Amps RMSThermal Offset: lo6 ohms, input to output w~th no protectionnetworkIsolation Voltage: >400 V peak input to output> 1500 VRMS to chassisRelay Lifetime: > lo8 at m~nimum load. > lo5 at full loadSwitchinn Seeed: Anv combmailon of channels can be clost?d~ -~ -simuitaneously. ~rograrnm~n~ and execution of a single ormultiple channel closure or ooen reauires 40 ms. Reoetitive7~ -changes of the same Option i15 assembly are limited to oneevery 1.5 seconds. Changes of the same assembly up to 25a second can be jumper enabled but will result in decreasedlifetime at full load.Maximum Leakage Current:(at 250 VRMS and 60 Hz)-1 mA RMS with no protection network6 mA RMS with protection networkProtection Network R = 47 Ohms t 20%.C = ,047 rF t 10%Minimum Input: 100 pA. 100 mV DC (for contact cleansing)Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com