12.07.2015 Views

Part 2

Part 2

Part 2

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Plug-In Assembly Configuration 41 3You can program the counter to send an interrupt to the 3497A when a measurementis complete and/or when the input signal period cannot be measured (anoverflow condition). In addition, a level change is available at the OUTPUT HlGH terminalwhen either of these two conditions occur and (if enabled), an interrupt is sentto the 3497A status register to set bit 1 (digital interrupt).If the input signal period can't be measured because the period is too long for themeasurement range selected, a counter overflow condition occurs and a level changeoutput and interrupt (when enabled) occurs. For example, if you tried to measurethe period of 1 MHz input, an overflow condition occurs since the input period exceedsthe counter limits.Pulse Width MeasurementIn pulse width measurement, the counter can measure one pulse width or average100 or 1000 pulse widths of an input signal with pulse widths which are 18 psecor wider. You can select input signal triggering from rising edge to falling edge orfalling edge to rising edge.You can program the counter to send an interrupt to the 3497A when a pulse widthmeasurement is complete or when the pulse width cannot be measured by thecounter (overflow condition). In addition, a level change pulse is available at the OUT-PUT HlGH terminal when either of these two conditions occur and (if enabled), aninterrupt is sent to the 3497A status register to set bit 1 (digital interrupt).If the input signal period can't be measured because the pulse width is too shortfor the measurement range selected, a counter overflow condition occurs and a levelchange output and interrupt (when enabled) occurs. For example, if you tried tomeasure the pulse width of a 1 MHz input, an overflow condition occurs since theinput pulse width exceeds the counter limits.Pulse OutputThe pulse output mode is a variation of the count down operation. In pulse output,the counter outputs a programmable number of square wave pulses (0 to 499999)at a specified frequency (0 to 1 kHz). The frequency of output pulses is half the inputsignal frequency. The input signal must be between 0 and 2 kHz with a pulsewidth greater than 5 psec.Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!