13.07.2015 Views

CJ2 CPU Unit Software User's Manual - CIP ETI

CJ2 CPU Unit Software User's Manual - CIP ETI

CJ2 CPU Unit Software User's Manual - CIP ETI

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

10 <strong>CPU</strong> <strong>Unit</strong> Functions1 Synchronous SignalWhen the power supply to the PLC is turned ON, the <strong>CPU</strong> <strong>Unit</strong> generates a synchronous signaland then starts initializing the synchronous data. The <strong>CPU</strong> <strong>Unit</strong>s and Synchronous <strong>Unit</strong>s alsostart internal processing at this time.2 Synchronous Input Data Refresh (Synchronous <strong>Unit</strong>s to <strong>CPU</strong> <strong>Unit</strong>)The Synchronous <strong>Unit</strong>s sent synchronous data to the <strong>CPU</strong> <strong>Unit</strong>.3 Synchronous Interrupt TaskThe <strong>CPU</strong> <strong>Unit</strong> executed the synchronous interrupt task. (Synchronous unit operation can beused without using the synchronous interrupt task.)4 Synchronous Processing TimeThe synchronous processing time is the time required for one series of synchronous operationprocessing in one synchronous operation cycle. It is the time from when the synchronous signalis generated until execution of the synchronous interrupt task has been completed. After the synchronousprocessing time, normal processing is performed until the synchronous control cyclehas expired.The synchronous processing time must be less than the synchronous operation cycle. (The maximumand present values of the synchronous processing time can be monitored in the SynchronousOperation Status Dialog Box of the CX-Programmer.)5 Synchronous Operation CycleWhen the synchronous operation cycle time has expired, the synchronous signal is generatedagain.6 Synchronous Output Data Refresh (<strong>CPU</strong> <strong>Unit</strong> to Synchronous <strong>Unit</strong>s)The <strong>CPU</strong> <strong>Unit</strong> sends synchronous data to the Synchronous <strong>Unit</strong>s.7 The overall process is repeated from step 2.Precautions for Correct UseThe <strong>CPU</strong> <strong>Unit</strong> interrupts normal processing during the synchronous input data refresh, synchronousinterrupt task execution, and synchronous output data refresh. The normal cycle time of the<strong>CPU</strong> <strong>Unit</strong> will be extended by the time required for these processes. Be sure that the control systemwill not be adversely affected if the cycle time is extended before using synchronous unitoperation.10-82 <strong>CJ2</strong> <strong>CPU</strong> <strong>Unit</strong> <strong>Software</strong> User’s <strong>Manual</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!