13.07.2015 Views

CJ2 CPU Unit Software User's Manual - CIP ETI

CJ2 CPU Unit Software User's Manual - CIP ETI

CJ2 CPU Unit Software User's Manual - CIP ETI

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

10 <strong>CPU</strong> <strong>Unit</strong> Functions10-8-3 Synchronous <strong>Unit</strong> Operation SpecificationsItemApplicable <strong>CPU</strong> <strong>Unit</strong>sSpecial I/O <strong>Unit</strong>s and <strong>CPU</strong>Bus <strong>Unit</strong>s that can be usedas Synchronous <strong>Unit</strong>sNumber of mountable Synchronous<strong>Unit</strong>sMounting location for Synchronous<strong>Unit</strong>sSynchronous operationcycle timeMaximum variation in synchronousoperation cycletimeI/O memory area for synchronizeddata exchange in<strong>CPU</strong> <strong>Unit</strong>Task number of synchronousinterrupt taskSpecification<strong>CJ2</strong>H-<strong>CPU</strong>6@(-EIP) <strong>CPU</strong> <strong>Unit</strong>s with unit version 1.1 or laterCJ1W-NC@@4 Position Control <strong>Unit</strong>s10 <strong>Unit</strong>s max.5 <strong>Unit</strong>s max. for CJ1W-NC@@4 Position Control <strong>Unit</strong>sSynchronous <strong>Unit</strong>s must be mounted on the <strong>CPU</strong> Rack. (They will not function ifmounted on an Expansion Rack.)0.5 to 10 ms (in 0.1-ms increments)Set in the PLC Setup.The following conditions must be met:• The synchronous processing time must be less than the synchronous operationcycle time.• The internal processing time of a Synchronous <strong>Unit</strong> must be less than the synchronousoperation cycle time.10 μsThe Synchronous Data Refresh Area is separated into two sections, one for inputdata from the Synchronous <strong>Unit</strong>s to the <strong>CPU</strong> <strong>Unit</strong> and one for output data from the<strong>CPU</strong> <strong>Unit</strong> to the Synchronous <strong>Unit</strong>s. The Synchronous Data Refresh Area is fromCIO 1200 to CIO 1295. The contents depends on the Synchronous <strong>Unit</strong>s.Interrupt task number 2 must be used.Synchronous unit operation can be used without using the synchronous interrupttask.10-84 <strong>CJ2</strong> <strong>CPU</strong> <strong>Unit</strong> <strong>Software</strong> User’s <strong>Manual</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!