4 <strong>CPU</strong> <strong>Unit</strong> Initialization4-3-2 Automatic AllocationWith automatic allocation, I/O tables are not created by the user. Every time the power supply is turnedON, I/O memory will be allocated to each <strong>Unit</strong> based on the locations of the <strong>Unit</strong>s. The allocated memoryis used for data exchange with the <strong>Unit</strong>s.There are no registered I/O tables, and the system will not check the <strong>Unit</strong> configuration.<strong>CJ2</strong>H-<strong>CPU</strong>68-EIP00 0000 CJ1W-ID20101 2000 CJ1W-AD041-V102 1500 CJ1W-CLK21-V103 000104 0001I/O TablesOpen slotOpen slot<strong>CPU</strong> <strong>Unit</strong><strong>Unit</strong>s00 01 02Location I/O memory(slot number) area address<strong>Unit</strong> typeCJ1W-CLK21-V1<strong>CPU</strong> Bus <strong>Unit</strong>CJ1W-AD041-V1Special I/O <strong>Unit</strong>Automatic allocation<strong>Unit</strong>sCJ1W-ID201Basic I/O <strong>Unit</strong>4-3-3 <strong>Manual</strong> AllocationWith manual allocation, the user creates I/O tables called registered I/O tables.You can create I/O tables by using one of the following methods with the CX-Programmer.• Creating I/O Tables Based on the Actual <strong>Unit</strong> ConfigurationWith this method, I/O tables are automatically created based on the configuration of actually mounted<strong>Unit</strong>s with the CX-Programmer connected online.• Editing I/O Tables <strong>Manual</strong>ly and Transferring Them to the <strong>CPU</strong> <strong>Unit</strong>With this method, the I/O tables are manually created offline by registering each <strong>Unit</strong> in the desiredlocation using the CX-Programmer, and the completed I/O tables are transferred to the <strong>CPU</strong> <strong>Unit</strong>.Whichever method is used, an I/O Setting Error will occur (A401.10 will turn ON) and operation will notstart if the configuration of connected <strong>Unit</strong>s is different from the unit configuration in the I/O tables whenthe PLC is turned ON.For details on I/O allocation methods, refer to 8-1 I/O Allocations. For details on creating I/O tables,refer to 8-2 Setting <strong>CPU</strong> Bus <strong>Unit</strong>s and Special I/O <strong>Unit</strong>s.4-10 <strong>CJ2</strong> <strong>CPU</strong> <strong>Unit</strong> <strong>Software</strong> User’s <strong>Manual</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!